The imageFORMULA utility will start.
3.
Click [Canon DR-XXXX USB], and then click
"Properties". (XXXX depends on the model in use.)
The scanner properties will be displayed.
4.
Click [Reset].
The counter value of the "Roller in use" will be reset.
5.
Click [OK] to close the scanner properties.

Removing and Reinstalling the Rollers

Follow the procedure shown below to remove and reinstall
the rollers when you need to clean or replace the Pickup,
Feed, or Retard Rollers.
CAUTION
• Turn OFF the power switch, and disconnect the power plug from
the power outlet when you remove or reinstall the rollers. Leaving
the power turned ON may result in an electric shock.
• Do not place excessive force on the rollers when removing or
reinstalling the rollers. Deformation of the rollers may cause feed
errors.
5-9
Chapter 5 Maintenance
Pickup Roller
Feed Roller
Retard Roller