Appendix
Error Code
753
OverTemp.Ballast1 Precaution
754
OverTemp.Ballast2 Precaution
760
OverTemp.DMD
761
OverTemp.Inlet
762
OverTemp.Lamp
764
OverTemp.Ballast1
765
OverTemp.Ballast2
781
Interlock Open
782
SystemI2cFail
783
EepromFail
785
SoftwareI2cFail
786
PreCooling
787
Lamp Door1 Open
788
Lamp Door2 Open
789
Ballast1UartError
790
Ballast2UartError
791
FanInitError
792
ExGpioFail
793
Notch Filter Open
800
Fan15 Stop
801
Fan16 Stop
810
Fan15 Stop Precaution
811
Fan16 Stop Precaution
86
Error message
Description
Set inside temperature (Ballast1) is close to over
temperature.
Set inside temperature (Ballast2) is close to over
temperature.
Set inside temperature (DMD) is abnormal.
Set inside temperature (Inlet) is abnormal.
Set inside temperature (Lamp) is abnormal.
Set inside temperature (Ballast1) is abnormal.
Set inside temperature (Ballast2) is abnormal.
Interlock is open.
Failed to control sensors connecting to GPIO chip.
(Slave board internal abnormality)
Slave MCU failed to read back all of data from EEPROM
on slave MCU board due to unexpected data or
something.
(Slave board internal abnormality)
I2C/UART conversion chip control failed on slave board.
(Slave board internal abnormality)
Failed to precool.
Lamp1 door (cover) is open.
Lamp2 door (cover) is open.
Communication error between slave MCU and ballast1.
Communication error between slave MCU and ballast2.
Failed to initialize fans.
Failed to control the signal connecting to Ballast.
(Slave board internal abnormality)
Notch Filter Cover is open.
Fan15 has stopped.
Fan16 has stopped.
Fan15 Stop Precaution
Fan16 Stop Precaution