NEC NC900C Installation Manual page 84

Dlp cinema projector
Hide thumbs Also See for NC900C:
Table of Contents

Advertisement

Appendix
Error Code
346
Green DAD1000 Reset Under Voltage Error
347
Green DAD1000 Offset Under Voltage Error
348
Green DAD1000 Thermal Shutdown Error
349
Blue Satellite Reports Reset
350
Blue Satellite Serial Link Error
351
Blue Satellite Firmware Configuration Error
352
Blue DAD1000 Bias Under Voltage Error
353
Blue DAD1000 Reset Under Voltage Error
354
Blue DAD1000 Offset Under Voltage Error
355
Blue DAD1000 Thermal Shutdown Error
356
RTC Error
370
ICP Frame Memory Test Result Fail
372
ICP Data Path Signature Test Result Fail
400
Enigma Comm Fail
410
System Error
411
Self Test Error
412
Install Release Package Error
413
Load Release Package Error
414
TI Login List Package Error
415
Security Officer Login List Package Error
419
Certificate or Key Error
420
ICP Communications Status
426
User Loader Integrity Error
427
Main Application Integrity Error
428
RNG Hardware Integrity Error
429
DRNG Algorithm Integrity Error
430
RSA Algorithm Integrity Error
431
AES Algorithm Integrity Error
432
HMAC Algorithm Integrity Error
433
SHA Algorithm Integrity Error
434
TLS Integrity Error
435
FPGA Configuration Integrity Error
436
FPGA CineLink 2 Decryption Integrity Error
437
RTC Error
442
FPGA Configuration Error
443
FPGA Temperature out of range
446
RNG Hardware Duplicate Output Error
447
DRNG Algorithm Duplicate Output Error
450
1.20V Supply out of range
451
1.80V Supply out of range
452
2.50V Supply out of range
453
3.30V Regulator out of range
458
SelfTest User Loader Integrity Error
459
SelfTest Main Application Integrity Error
460
SelfTest RNG Hardware Integrity Error
461
SelfTest DRNG Algorithm Integrity Error
462
SelfTest RSA Algorithm Integrity Error
463
SelfTest AES Algorithm Integrity Error
84
Error message
Description
ICP system status error
ICP system status error
ICP system status error
ICP system status error
ICP system status error
ICP system status error
ICP system status error
ICP system status error
ICP system status error
ICP system status error
Indicates that ICP RTC is set to a date before January 1,
2009, and is likely invalid. If the year value is less than
2009, then the time is considered to be "invalid".
ICP self test error due to "Frame memory error"
ICP self test error due to "Data Path Signature Test Result
Fail"
No communication with the Enigma board.
Enigma Status error
Enigma Status error
Enigma Status error
Enigma Status error
Enigma Status error
Enigma Status error
Enigma Status error
Enigma fails to do logical marriage to ICP when Enigma
powers up. Because of no communications with ICP
during logical marriage.
Enigma is in FIPS error state. (Integrity check error)
Enigma is in FIPS error state. (Integrity check error)
Enigma is in FIPS error state. (Integrity check error)
Enigma is in FIPS error state. (Integrity check error)
Enigma is in FIPS error state. (Integrity check error)
Enigma is in FIPS error state. (Integrity check error)
Enigma is in FIPS error state. (Integrity check error)
Enigma is in FIPS error state. (Integrity check error)
Enigma is in FIPS error state. (Integrity check error)
Enigma is in FIPS error state. (Integrity check error)
Enigma is in FIPS error state. (Integrity check error)
Indicates that Enigma RTC is set to a date before January
1, 2009, and is likely invalid. If the year value is less than
2009, then the time is considered to be "invalid"
Enigma Status error
Enigma Status error
Enigma is in FIPS error state. (Integrity check error)
Enigma is in FIPS error state. (Integrity check error)
Enigma Status error
Enigma Status error
Enigma Status error
Enigma Status error
Enigma is in FIPS error state. (Self test result)
Enigma is in FIPS error state. (Self test result)
Enigma is in FIPS error state. (Self test result)
Enigma is in FIPS error state. (Self test result)
Enigma is in FIPS error state. (Self test result)
Enigma is in FIPS error state. (Self test result)