Download Print this page

Maytag MGD6300TQ - Bravos Gas Dryer Use And Care Manual page 7

Fabric care system gas dryer
Hide thumbs Also See for MGD6300TQ - Bravos Gas Dryer:

Advertisement

Available languages

Available languages

ect cat
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
120 Volt, 60 Hz., AC only, 15- or 20-amp
fused electrical
supply
is required.
A time-delay
fuse or circuit
breaker
is recommended.
It is also recommended
that a separate circuit
serving
only this dryer be provided.
GROUNDING
iNSTRUCTiONS
• For a grounded, cord-connected
dryer:
This dryer must be grounded, in the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING:
improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with the
dryer: if it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
SAVE THESE
INSTRUCTIONS
Explosion
Hazard
Use a new CSA International
approved
gas supply
line.
install a shut=off valve.
Securely tighten
all gas connections.
if connected to LP, have a qualified
person make sure
gas pressure does not exceed 13" (33 cm) water
column.
Examples
of a qualified
person include:
licensed heating personnel,
authorized
gas company personnel, and
authorized
service
personnel.
Failure to do so can result in death, explosion,
or fire.
Gas Type
Natural
Gas:
This dryer is equipped
for use with
Natural
gas. It is design-certified
by CSA International
for
I.P (propane
or butane) gases with
appropriate
conversion.
Your dryer must have the correct
burner
for the type of gas in your home.
Burner
information
is located
on the rating plate in the door well of your dryer. If this information
does not agree with
the type of gas available,
contact
your dealer or call the phone
numbers
referenced
on the front page of this manual.
LP gas conversion:
Conversion
must be made by a qualified
technician.
No attempt
shall be made to convert
the appliance
from the gas specified
on the model/serial
rating plate for use with
a different
gas without
consulting
your gas company.
For information
on ordering
an LP conversion
kit, please refer to the "Assistance
or Service"
section.
Ask for
Part Number
49572.
Gas Supply Line:
Must include
Vs" NPT minimum
plugged
tapping
accessible
for test gauge connection,
immediately
upstream
of the gas connection
to the dryer (see illustration).
V2" IPS pipe is recommended.

Advertisement

loading