Download Print this page

Maytag MGD6300TQ - Bravos Gas Dryer Use And Care Manual page 6

Fabric care system gas dryer
Hide thumbs Also See for MGD6300TQ - Bravos Gas Dryer:

Advertisement

Available languages

Available languages

Installation
C learances
The location
must be large enough
to allow the dryer door to open fully.
Dryer Dimensions
cm)
*Most installations
require
a minimum
5" (12.7 cm) clearance
behind
the dryer for the
exhaust
vent with elbow.
See "Venting
Requirements."
Installation
spacing
for recessed
area or closet
installation
The following
spacing dimensions
are recommended
for this dryer. This dryer has been tested
for spacing
of O" (O cm) clearance
on the sides and rear. Recommended
spacing
should
be
considered
for the following
reasons:
Additional
spacing should
be considered
for ease of installation
and servicing.
Additional clearances might be required for wall, door and floor moldings.
Additional
spacing should
be considered
on all sides of the dryer to reduce
noise transfer.
For closet installation,
with
a doo_; minimum
ventilation
openings
in the top and bottom
of the door are required.
I.ouvered
doors with equivalent
ventilation
openings
are
acceptable.
Companion appliance spacing should also be considered.
Additional
spacing is required
if you exhaust
out the rear of the dryer to either the right or
left side.
_r
3"*
(310cm2) !
24in'2'JJ
3"*
(155 cm2qI_"
I-'_.6cm )
1"_ I_ 29"_ _1"
_11"*1 _ 29,/," _1s" ÷
-T
(2.5cm) (73.7crn) (2,5 crn) (2.5 cm)(74,3 c rn)(12.7crn)
A
B
C
A. Recessed
area
B. Side view - closet
or confined
area
C. Closet
door with
vents
*Required spacing
Mobile
home
- Additional
installation
requirements
This dryer is suitable
for mobile
home installations.
The installation
must conform
to the
Manufactured
Home Construction
and Safety Standard,
Title 24 CFR, Part 3280 (formerly
the
Federal Standard
for Mobile
Home Construction
and Safety, Title 24, HUD
Part 280) or
Standard
CAN/CSA-Z240
MH.
Mobile
home
installations
require:
Metal exhaust
system hardware,
which
is available
for purchase
from your dealer.
Mobile
home
Installation
Kit Part Number
346764.
See "Tools
and Parts" section for
information
on ordering.
Special provisions
must be made in mobile
homes to introduce
outside
air into the dryer.
The opening
(such as a nearby window)
should
be at least twice
as large as the dryer
exhaust
opening.