Download Print this page

Step 6: Final Wiring - Hunter 23710 Installation Instructions Manual

Type 2

Advertisement

CAUTION: To ensure proper engagement of the canopy assem-
bly screws, the canopy must fit snug against the top of the fan.
CAUTION: Do not lift motor by wires.
D.
Being careful not to scratch the canopy finish, hang the fan
from the hook in the ceiling plate using the round hole in the top
of the canopy. See Figures 5A and 5B.
GREEN
GROUND WIRE
CONNECTOR
CANOPY
FAN
Figure 5B. Hanging the Fan
Step 5-2: Ball Hanging Version
CAUTION: Do not lift motor by wires.
A.
First, place the canopy trim piece on top of the fan as shown
in Figure 5C. Insert the pipe nipple through the canopy and feed
the lead wires from the top of the fan through the pipe nipple.
NOTE: The lead wires should extend out the top of the fan at
least six inches. Screw the pipe nipple into the adaptor on the top
of the fan until tight (at least 4 -1/2 turns). Tighten the pipe nip-
ple setscrew to lock the pipe nipple to the adaptor. The setscrew
must be tightened very securely. See Figure 5C. Failure to tight-
en the setscrew could result in the fan falling.
SETSCREW
(tighten securely)
CANOPY TRIM
B.
Before hanging the fan from the ceiling plate, align and
engage the (2) tabs in the bottom of the canopy with the (2)
grooves in the hanger ball. See Figure 5D.
FORM NO. 41184-01 10/05
CEILING PLATE
HOOK
LEAD WIRES
CANOPY
PIPE NIPPLE
ADAPTOR
Figure 5C
Using the round hole in the top of the canopy, hang the fan from
the hook in the ceiling plate. Make sure both tabs in the canopy
remain engaged with the grooves in the ball. Be careful and
don't scratch the finish while hanging the fan. See Figure 5B.
Figure 5D. Aligning Tab & Groove
NOTE: When attaching the canopy to the ceiling plate on a
vaulted ceiling, make sure the two tabs in the center hole of the
canopy align vertically so that the tabs properly engage the two
grooves in the hanger ball. See Figure 5D. If the tabs do not
remain engaged with the two grooves in the hanger ball they
could deform and the fan could hang at an angle.

Step 6: Final Wiring

A.
Connect electrical supply leads to the leads from motor,
using approved connectors. Connect black electrical supply lead
to the black motor lead and the black with white stripe motor lead
(see Note). Connect the white electrical supply lead to the white
motor lead. Connect the ground wire to the green leads from the
motor and ceiling plate. See Figure 5B.
NOTE: If a separate wall switch will be used to control a lighting
accessory, connect the black wire with white stripe to the wall
switch lead. The wall switch must be acceptable for use as a
general-use switch.
CAUTION: No bare wire or wire strands should be visible after
making connections.
B.
After making the wire connections, the wires should be
spread apart with the white and green wires on one side of the
outlet box, and the black and black/white wires on the other side
of the box.
The splices should be turned upward and pushed carefully up into
the outlet box.
Step 7: Finish Fan Assembly
A.
Remove the fan from the ceiling plate hook. Make sure you
do not break any wire connections. The canopy has (3) suspen-
sion flanges located on top. See Figure 6. The ceiling plate has
(3) mating slots. See Figure 6A.
CANOPY
FLANGE
Figure 6
-
-
3
GROOVE IN
HANGER BALL
TAB IN BOTTOM
OF CANOPY
CEILING
PLATE
SLOT
Figure 6A
©2005 HUNTER FAN CO.

Advertisement

loading

This manual is also suitable for:

23714