EdgeStar AP410W Owner's Manual

EdgeStar AP410W Owner's Manual

Edgestar portable air conditioner owner's manual ap410w
Hide thumbs Also See for AP410W:

Advertisement

1

Advertisement

Table of Contents
loading

Summary of Contents for EdgeStar AP410W

  • Page 2: Table Of Contents

    Table of contents Table of contents Thank you Energy saving tips Notes Specifications Safety precautions Parts Front view Rear view Accessories Installation Installing the exhaust hose Window installation Wall installation Notes Control panel LED indicators Buttons Remote control Setting up the remote control Notes Caution Remote control functions...
  • Page 3: Thank You

    Thank you Thank you for purchasing an EdgeStar portable air conditioner. Rest assured that all EdgeStar products are designed and manufactured to the highest standards. We would like you to be able to fully utilize all features of this portable air conditioner, so please take the time to read this owner’s manual in full prior to using the unit.
  • Page 4: Specifications

    Safety precautions: 1. Transport the portable air conditioner in an upright position only. If the unit is tipped over, make sure it stands upright for at least 3 hours prior to turning it on. 2. Always place the unit on a level surface.
  • Page 5 10. Do not tilt the portable air conditioner. 11. Do not cover or obstruct the intake or outlet grills. 12. Do not use the portable air conditioner in a wet room- such as a bathroom or laundry room- to avoid the possibility of shock.
  • Page 6: Parts

    Parts Front view 1. Control panel 2. Adjustable louvers 3. Carry handles 4. Caster wheels Rear view 1. Air inlet 2. Exhaust port 3. Power cord hooks 4. Caster wheels 5. Drain plug (a plastic drain cap covers a rubber stopper)
  • Page 7: Accessories

    Accessories Drain hose Exhaust hose Drain tray Remote and batteries Rectangular vent connector Carbon filter Owner’s manual and warranty card Round adapter Cap for round adapter Plastic window kit and screws...
  • Page 8: Installation

    Installation Installing the exhaust hose In order to be used effectively, the exhaust hose must be mounted to the back of the unit. 1. Make sure the rectangular vent connector is fitted to one end of the exhaust hose and fit the round adapter to the other end. 2.
  • Page 9: Window Installation

    You may need to use screws to hold the window kit in place. 3. Position the portable air conditioner near the window, extend the exhaust hose as far as you need to, and place the end of the exhaust hose (which is in the round adapter) into the hole in the window kit.
  • Page 10: Wall Installation

    4. Replace the round adapter into the wall and screw it into place. 5. Move the portable air conditioner into place near the wall and insert the exhaust hose into the round adapter. Twist the exhaust hose into the adapter in a clockwise direction.
  • Page 11: Notes

    3. The exhaust hose supplied with the portable air conditioner has been specifically designed for this air conditioner. Do not lengthen the hose or replace it with any other hose.
  • Page 12: Control Panel

    Control panel LED indicators 1. “ST” When this light is lit (when the TEMP. UP or TEMP. DOWN buttons are pressed), the LED display shows the temperature that the unit is set to cool to. 2. “RT” When this light is lit the LED display shows the current ambient temperature in the room.
  • Page 13: Buttons

    1. Remove the cover from the back of the remote control. 2. Insert 2 AAA batteries. 3. Point the remote control at the portable air conditioner (make sure the air conditioner is plugged in) and press the button for the operation that you want.
  • Page 14: Caution

    Do not mix different types of batteries in the remote control. Remote control functions 1. LCD Display This displays the time and the settings selected for the portable air conditioner 2. Mode selection button This button toggles between the different modes of the portable air conditioner 3.
  • Page 15 This button activates or deactivates the “On timer.” As noted in more detail above, the On timer turns the portable air conditioner on after a number of hours (you select the number of hours) elapses. To set the On timer using the remote control, the portable air conditioner must be off.
  • Page 16: Regulating Airflow Direction

    Regulating airflow direction To adjust airflow, the louvers on this portable air conditioner can be adjusted up and down and from right to left. To adjust the horizontal louvers, gently move them up or down as desired. To adjust the vertical louvers, move the handle at the bottom of the...
  • Page 17: Manual Drainage

    Manual drainage When the portable air conditioner is in cooling or dry mode, it will dehumidify the air. The water dehumidified from the air will be collected in an internal reservoir. This water will be used to help cool the compressor and it will be evaporated and exhausted out the exhaust hose.
  • Page 18: Direct Drainage

    Notes: Always unplug the portable air conditioner before performing cleaning or maintenance. Never hose this air conditioner down or attempt to clean it with a dripping wet sponge or cloth. Cleaning the exterior • Use a soft damp cloth to wipe the body clean •...
  • Page 19: Installing The Charcoal Filter

    4. Insert the filter frame back into the portable air conditioner. Cleaning the prefilter 1. Remove the filter frame from the portable air conditioner (as described in step one of “Installing the charcoal filter”). 2. Use a vacuum cleaner’s brush attachment to suck the accumulated dust off the prefilter.
  • Page 20: Troubleshooting

    Troubleshooting If the portable air conditioner is not working properly, it is usually due to a minor problem that the user can handle. Before calling customer service, refer to the following chart for troubleshooting: Problem The air conditioner will not function at all The air conditioner starts and then cuts out.
  • Page 21 The drain stopple and plug are not installed The unit is not on a level surface The air conditioner is too The unit is positioned on a loud. hard, uneven floor, and is vibrating. The Run LED is blinking...
  • Page 22 LCDI plug wring instruction : This unit is provided with Leakage Current detection interruption circuit (LCDI )built into the plug of the power supply cord . This device provides protection to reduce the risk of fire due to arcing faults in the power–supply cord. Before use, follow the “Plug Testing Instructions”...
  • Page 23: Limited Warranty

    DESCRIPTION OF WARRANTY SERVICE: All defective product components covered by this warranty will be repaired or replaced, at EdgeStar’s option, free of charge on a mail-in basis to EdgeStar’s authorized repair facility during the first 90 days from the date of original purchase.
  • Page 24 866-319-5473. Please have your order receipt available to confirm the date of purchase. Once an EdgeStar authorized representative has confirmed that your product is eligible for warranty service, the product must be returned to an EdgeStar authorized repair facility. The purchaser is solely responsible for prepaying all shipping related costs to and from the repair facility.

Table of Contents