Nitrous Electrical System Installation Procedures; Nitrous Relay And Fuse Holder Installation - Edelbrock 71001 Installation Manual

Performer series nitrous system for 2002-later acura rsx, rsx type s, and 2003 honda civic si
Table of Contents

Advertisement

3.4

Nitrous Electrical System Installation Procedures

Determine the location of the Relay and Fuse Holder wire harness. Most common installations locate these components inside
the driver's compartment and close to the fuse panel under the dash. You can also mount the Relay and Fuse Holder and
harness close to the battery. However, these connectors are water-resistant, not waterproof, so care is required when mounting
this assembly under the hood of your vehicle.
Wire Color
Red
Red
Black
Black
Black
Blue
White
White
3.5

Nitrous Relay and Fuse Holder Installation

The wire harness attached to the relay and fuse holder includes 8 feet of color-coded wires to make the electrical system
installation for your Edelbrock Nitrous System as easy as possible. We recommend that you do not cut any lengths of wires
from the wire harness or complete the wiring of the nitrous system until all of the mechanical components are securely mounted
in their permanent locations.
Once all of the solenoids and switches are placed, then route the un-cut wires from the harness to each location allowing
enough wire length on each circuit to not interfere with operating linkages, heat sources, brackets, etc. Pay particular attention
to sharp edges along the route of your wire harness as they can chafe the wire and cause your system to fail.
After you have accounted for the routing of your wires, follow the Wire Harness Schematic on page 15 and use the Origin and
Destination Map as a guide for which electrical connectors are used in each circuit.
Once you have decided the location of the relay and fuse holder, secure them with fasteners (not included with kit) such as
sheet metal screws, bolts and nuts, etc. Allow for some slack in the red wire that connects the relay and fuse holders together.
When mounting your relay and fuse holder, make sure the mounting surface is strong enough to support servicing the relay and
fuse. Also, ensure you allow for some slack in the wire that joins the fuse holder to the relay mount. This will avoid any potential
loss of power due to stress on the wire harness.
The fuse is covered by the fuse mount housing.
The relay for the Performer system is 30 amps, and the fuse is 15 amps.
©2002 Edelbrock Corporation
Rev. 9/02
Wire Schematic Origin and Destination Map
System
Bat Voltage
Relay Harness
Arming Switch
Underdash
Relay Ground
Relay Harness
Solenoid Ground
Solenoids
Arming Switch Grnd.
Arming Switch
Solenoid Power
Relay Harness
Microswitch
Relay Harness
Microswitch
Arming Switch
Page 16 of 21
Origin
Destination
Bat. Volt. Signal
Switched 12v
Chassis Ground
Chassis Ground
Chassis Ground
Solenoids
Microswitch
Microswitch
Terminal Used
Ring
Spade/Wire Intercept
Ring
Ring
Ring
Spade
Spade
Spade
Brochure No. 63-0142
Catalog #71001

Advertisement

Table of Contents
loading

Table of Contents