I Want To Clear All The Items In Powertouch Iii And Make It To The Factory-Set Default Condition; The Rf Remote Control Function Does Not Work; Receiver/Tuner; My Receiver Won't Turn On And The Standby Indicator Is Flashing - Kenwood Sovereign VR-5900 User Manual

Hide thumbs Also See for Sovereign VR-5900:
Table of Contents

Advertisement

Receiver/Tuner

I want to clear all the items in PowerTouch III and make it to the
factory-set default condition.
While holding the CONFIRM and VOLUME DOWN buttons together,
press and release the RESET button under the battery cover (see above
diagram). Do not release the CONFIRM and VOLUME DOWN but-
tons until a short beep indicating the completion of setting is heard.
After the above, all settings are reset to the factory settings.

The RF remote control function does not work.

Connect the antenna. See page 33 of the Connections and Setup Guide.
Make sure that the correct RF band is selected. see page 46 of the
Connections and Setup Guide.
The operation range of the PowerTouch III will be influenced accord-
ing to the material of the obstacles between the PowerTouch III and
the receiver. Please confirm that there is no such influence.
Make sure that no interference from electrical appliances occurs.
Receiver/Tuner

My receiver won't turn on and the STANDBY indicator is flashing.

Your receiver is in the "protection" mode.
Check that:
The speaker system's impedance is not too low. See Chapter One of
the Connections and Setup Guide.
The speaker wires are not short-circuited. Test the wires as follows to
find the shorted wire and replace it:
1 Turn off the receiver, disconnect the positive and negative speaker
wires of the RIGHT FRONT speaker from the receiver, and turn
the receiver back on.
2 If the STANDBY indicator stops flashing, replace this wire.
3 If the STANDBY indicator does not stop flashing, turn off the re-
ceiver, reconnect the speaker wires, and repeat the first step for the
next speaker.
4 Continue until you have isolated and replaced the shortedwire.
5 See Chapter One of the Connections and Setup Guide.
If none of the above solutions work, reset the microprocessor:
1. Turn the receiver off.
2. Unplug the receiver.
104