Solving Communication Problems - 3Com 5500-EI PWR Getting Started Manual

Switch 5500 family
Hide thumbs Also See for 5500-EI PWR:
Table of Contents

Advertisement

64
C
5: P
HAPTER
ROBLEM
Solving
Communication
Problems
S
OLVING
3 Power cycle the unit. To do this, remove and reconnect the AC mains
supply. If the unit has no AC main supply, remove and reconnect the DC
RPS supply.
4 If another fan failure warning message is generated via the Command
Line Interface or the Web interface, return the unit to 3Com.
Unit fails, no SNMP fan failure message is received
1 Power cycle the unit. To do this, remove and reconnect the AC mains
supply. If the unit has no AC mains supply, remove and reconnect the DC
RPS supply.
2 Check the command line interface (display logbuffer command)
to determine whether a thermal shutdown has occurred.
3 If no, return the unit:
If yes, check that:
The air vents are not obstructed.
The ambient temperatures and environmental conditions meet those
specified in
Appendix
4 Power cycle the unit. If a further thermal shutdown occurs, and all
environmental conditions are satisfactory, return the unit to 3Com.
Error message indicating that the SFP transceiver is invalid
The Switch has identified that the SFP does not meet the minimum
requirements for the Switch and has disabled the port. To correct this
problem, completely remove the SFP and replace it with a 3Com
approved SFP. See
Error message indicating that the SFP transceiver is faulty
To correct this problem, completely remove the SFP and then reinsert it.
Alternatively, insert another identical SFP. If the problem persists, contact
3Com Technical Support.
If you experience communication problems with the Switch, ensure that:
The Switch IP address and Management VLAN ID has been
configured.
C.
"Approved SFP Transceivers"
on
page
31.