26
C
2: I
HAPTER
NSTALLING THE
S
WITCH
Table 6
below, outlines the behavior of the Switch when changes occur to
the power system, such as removing the AC mains cable when the RPS is
attached. The responses to the different power inputs are controlled by
the Switch's internal power supply and not by the RPS.
Table 6 Switch Power Inputs
Power Input before
User Intervention
AC mains and RPS
AC mains and RPS
RPS only
AC mains
3Com's RPS solution uses 48V DC power distribution. The RPS system
provides bulk 48V DC power that is separately distributed to a number of
network switches.
Each RPS consists of a shelf which can house from one to six rectifiers, a
Distribution Module and a Management Module.
The RPS generates 48V DC power using power supply units (or rectifiers).
The outputs of the rectifier(s) are connected together so that the total
48V power available can be increased by adding additional rectifiers. For
example, three 1500W rectifiers can provide up to 4500W. Hot removal
or insertion of a rectifier will not affect the 48V DC output voltage.
Table 7 shows an example of the total power available from a number of
1500W rectifiers.
A minimum of two rectifiers are required for each shelf to provide N+1
rectifier redundancy.
Power Input after
User Intervention
Correct Response
RPS only
The unit remains powered by the RPS.
AC mains only
The unit is powered by the AC mains.
AC mains and RPS
The unit remains powered by the RPS.
AC mains and RPS
The unit is powered by the RPS.