A.O. Smith TWI 35-130 Instruction Manual page 27

A.o. smith gas water heater installation user and service manual
Hide thumbs Also See for TWI 35-130:
Table of Contents

Advertisement

Subject
Wall fl ue terminal set:- 1x Wall fl ue termi-
nal (incl. wall plate & clamping strip)
- 1x Pipe 500 mm
- 1x Bend 90°
Piping material
Pipe diameters
(1) It is not allowed to use any other wall fl ue terminal. You can order the wall fl ue terminal mentioning the item
number with A.O. Smith, manufacturer or wholesaler's.
Instruction manual TWI 35-130 G/TWI 45-190 G
Device with concentric fl ue gas discharge material
According to the table the maximum length is 20 metres and the allowed
number of 90° bends is 5. Both requirements are met.
Specifi cations
Caution
A.O. Smith prescribes the use of a roof or wall fl ue terminal approved for
the device with the C13 and C33 device types. Use of an improper roof or wall
fl ue terminal may lead to an error.
Specifi cation of concentric wall fl ue terminal C13
Item no.:
Construction:
Manufacturer:
Type:
Construction:
Flue gas discharge:
Air supply:
Flue gas discharge:
Air supply:
Description
TWI 35-130: 0302 515
(1)
TWI 45-190: 0302 515
(1)
Concentric
Muelink & Grol
M2000 MDV SEC
Concentrique
Thick-walled aluminium with lip-ring sealing
Thin-wall galvanised sheet steel
TWI 35-130: Ø 80 mm
TWI 45-190: Ø 80 mm
TWI 35-130: Ø 125 mm
TWI 45-190: Ø 125 mm
IMD-0532 R0
25

Hide quick links: