Cr_Tempwarn Command - Canon LV-7392A Command List

Expand serial command functional specifications
Hide thumbs Also See for LV-7392A:
Table of Contents

Advertisement

LV-7292A/LV-7297A/LV-7392A/LV-7393A/LV-7398A/LV-8227A/LV-7292M/LV-7297M/LV-8227M

9.12.5 CR_TEMPWARN Command

Command
"CR_TEMPWARN"[CR]
Get the temperature inside a projector and its condition if it is abnormal
temperature or close to abnormal temperature
Details
If there are several sensors installed, it is possible to get information from all the
sensors at once.
Acceptable
%a
Response
%b
%c
Unacceptable
Expand Serial Command Functional Specifications
"000_%a_%b_%c"[CR]
%a -------------------- Sensor 1 status
%b -------------------- Sensor 2 status
%c -------------------- Sensor 3 status
"W" ---- Approach or reach abnormal temperature
(dangerous temperature)
"S" ---- Far from abnormal temperature (safe temperature)
"N" ---- Sensor detects no abnormal temperature
[Example]
"S_W_S"[CR] means Sensor 1 detects safe temperature, Sensor
2 detects abnormal temperature and Sensor 3 detects safe
temperature
Note) When the temperature difference between Sensor 1 and 3
reaches specific value, some of the models detect it as Abnormal
temperature. In this case, the 3rd data shows if the temperature
difference between Sensor 1 and 3 is dangerous state or not. The
3rd data means temperature abnormality due to Sensor 3
When abnormal temperature is not detected by sensor, "N" (No
connection with temperature abnormality) is returned.
"Error Code" [CR]