Fcfeerror Group - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference Manual

Brocade fabric os mib reference guide v6.1.0 (53-1000602-02, june 2008)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

3
fcFxPortBbCreditModel 1.3.6.1.2.1.75.1.2.3.1.12
fcFxPortBbCreditModel 1.3.6.1.2.1.75.1.2.3.1.12
Identifies the BB_Credit model used by the Fx_Port. The regular model refers to the buffer-to-buffer
flow control mechanism defined in FC-PH [1] used between the F_Port and the N_Port. For
FL_Ports, the alternate buffer-to-buffer flow control mechanism as defined in FC-AL [4] is used
between the FL_Port and any attached NL_Ports.

fcFeError Group

This group consists of tables that contain information about the various types of errors detected.
The management station might use the information in this group to determine the quality of the
link between the Fx_Port and its attached Nx_Port.
Implementation of this group is optional.
278
Fabric OS MIB Reference
53-1000602-02

Advertisement

Table of Contents
loading

Table of Contents