Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference Manual page 479

Brocade fabric os mib reference guide v6.1.0 (53-1000602-02, june 2008)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

entPhysicalClass 1.3.6.1.2.1.47.1.1.1.1.5
An indication of the general hardware type of the physical entity.
An agent should set this object to the standard enumeration value that most accurately indicates
the general class of the physical entity, or the primary class if there is more than one.
If no appropriate standard registration identifier exists for this physical entity, then the value
other(1)
Brocade 300 switches can have the following hierarchy of physical objects:
Brocade 5100 switches can have the following hierarchy of physical objects:
Brocade 5300 switches can have the following hierarchy of physical objects:
Brocade DCX directors can have the following hierarchy of physical objects:
Brocade 12000, 24000, and 48000 directors can have the following hierarchy of physical objects:
Brocade 3900 switches can have the following hierarchy of physical objects:
Brocade 4100 switches can have the following hierarchy of physical objects:
Fabric OS MIB Reference
53-1000602-02
is returned. If the value is unknown by this agent, then the value
Chassis: One entry (one row)
Container: One entry for each FRU slot (one blade, one power supply, three fans)
Module: one entry for blades, one entry for power supply, and three entries for fans.
Chassis: One entry (one row)
Container: One entry for each FRU slot (one blade, two power supplies, two fans)
Module: One entry for blades, two entries for power supplies, and two entries for fans.
Chassis: One entry (one row)
Container: One entry for each FRU slot (one blade,two power supplies, three fans)
Module: One entry for blades, two entries for power supplies, and three entries for fans.
Chassis: One entry (one row)
Container: One entry for each FRU slot (eight port blades, two CPs, four power supplies,
three fans)
Module: Eight entries for port blades, two entries for CPs, four entries for power supplies,
and three entries for fans.
Chassis: One entry (one row)
Container: One entry for each FRU slot (eight port blades, two CPs, four power supplies,
three fans)
Module: Eight entries for port blades, two entries for CPs, four entries for power supplies,
and three entries for fans.
Chassis: One entry (one row)
Container: One entry for each FRU slot (one switch blade, two power supplies, six fans)
Module: One entry for switch blade, up to two entries for power supplies, and up to six
entries for fans.
Chassis: One entry (one row)
Container: One entry for each FRU slot (one switch blade, two power supplies, three fans)
entPhysicalClass 1.3.6.1.2.1.47.1.1.1.1.5
4
is returned.
unknown(2)
463

Advertisement

Table of Contents
loading

Table of Contents