Force Control; Troubleshooting Leds - Chamberlain LiftMaster Professional SL585 Installation Manual

Heavy duty slide gate operator heavy duty, harsh environment slide gate operator
Hide thumbs Also See for LiftMaster Professional SL585:
Table of Contents

Advertisement

CONTROL BOARD PROGRAMMING AND FEATURES
(CONTINUED)

FORCE CONTROL

Set the force control pot such that the unit will complete a full
cycle of gate travel but can be reversed off an obstruction without
applying an unreasonable amount of force. On most operators
this will be around the middle of the range.
NOTE: For LED location refer to illustration on previous page.
DIAGNOSTICS (LEDS AND CODES)
There are three diagnostic LEDs. Two red LEDs (OLS, CLS) are
indicators for the open and close limits. The LEDs are illuminated
when the limit switch contacts are closed.
The third amber LED (DIAG) is used to blink out diagnostic
codes. The number is the count of the number of times the LED
is on in an 8 second period. The LED is on for approximately
1/2 second and repeats every second until the number is reached.
There will be a pause following each pulse cycle (1-6 pulses) to
differentiate between the different diagnostic codes.
RELAY DRIVE TROUBLESHOOTING LEDS
There are 5 troubleshooting LEDs on relay drives K1 through K5. These LEDs will be illuminated when the microcontroller relay drive
is activated.
LED
D6
D5
D4
D3
D2

TROUBLESHOOTING LEDS

There are 9 troubleshooting LEDs.
LED
D11
D13
D15
D17 (Green)
D19
D21
D24
D29
D31
Force Control
Max.
Min.
LED NAME
Contactor A
Contactor B
SAM
Lock
Alarm
LED NAME
Radio
Shadow
Hard Close
Stop
Soft Open
Hard Open
Interrupt (Safety) Loop
Obstruction Open
Obstruction Close
LED Code
Diagnostic Meaning
Flashed
OFF
Normal operation
1
Single entrapment sensed
2
Double entrapment
3
Failed or no hall
effect sensor
4
Exceed maximum motor
run time
5
Limit fault
6
Loss of communications
between master and
second during run mode
On No
Motor not learned
Flash
* Hard inputs include open override, close override and
stop inputs.
DESCRIPTION
On when Contactor A is activated
On when Contactor B is activated
On when SAM relay is activated
On when Mag Lock relay is activated
On when Alarm Relay is activated
DESCRIPTION
On when Radio switch is activated
On when Shadow Loop is activated
On when Close switch is activated
On when Stop switch is not activated
On when Open switch is activated
On when Open switch is activated
On when Interrupt/Safety Loop activated
On when Edge is activated or when Photo Eye
Beam is broken
On when Edge is activated or when Photo Eye
Beam is broken
25
Cleared By
N/A
Control Input
Hard Input*
Removal of
problem
Hard Input*
Control Input
Removal of
problem
Completion
of Motor
Learn Routine

Hide quick links: