Removing The Front Uid Module; Installing The Front Uid Module; Verifying Component Replacement - HP 418800-B21 - StorageWorks Modular Smart Array 70 Storage Enclosure Maintenance And Service Manual

Modular smart array enclosure
Hide thumbs Also See for 418800-B21 - StorageWorks Modular Smart Array 70 Storage Enclosure:
Table of Contents

Advertisement

Blue = Identified
Blue flashing = Active remote management
Off = No active remote management
Check the host log for errors.

Removing the front UID module

Power down the enclosure:
1.
Power down any attached servers. See the server documentation.
a.
Press the Power On/Standby button on the enclosure.
b.
Wait for the system power LED to go from green to amber.
c.
Disconnect the power cords.
d.
Remove the plastic bezel (1).
2.
Remove the T-10 screw to release the module from the chassis (2).
3.
Remove the front UID module (3).
4.

Installing the front UID module

To install the front UID module, reverse the removal procedure:
Attach the module to the chassis, securing it with a T-10 screw.
1.
Install the plastic bezel.
2.
Power up the enclosure.
3.

Verifying component replacement

After replacing the front UID module, check the front UID module status LED.