MOUNTING AND WIRING OF RESET SWITCH

STEP 7

The reset switch allows the operator to
be reset upon the event of a double
entrapment alarm. When such an event
occurs the alarm will continuously
sound and the operator will not have
any functionality until the board is reset.
1.
Disconnect power to the operator.
2. Mount reset switch at a minimum of 6' away from the gate/door jambs (Figure 1).
3. Plug the interface cable (Figure 2) into the J5 receptacle on the Omni control
board (Figure 3).
4. Connect like wires from the reset switch to the interface cable. Twist together with wire
nuts. NOTE: The wire connecting the interface cable to the reset switch is not provided.
Figure 1
Figure 2
CENTER
SAFETY
EXIT
Figure 3
QCC
W4
A
B
G B
A
SYSTEM ON
OPEN
STOP
MS LINK
CLOSE
MAGLOCK
ALARM
ARMED
M/ S L I NK
SENSORS
To prevent possible SERIOUS INJURY or
DEATH from electrocution, disconnect
electric power to operator BEFORE
installing.
ALL electrical connections MUST be
made by a qualified individual.
DC-BACKUP
TIMER
POWER
60
3
OVERLOAD
1
3
OFF
ON
MADE IN USA
1
3
1
3
OPEN LEFT
OPEN RIGHT
FIRE
STRIKE
RADIO
GATE
DEPT.
OPEN
RECEIVER
LOCKED
EXIT
SAFETY
CENTER
RESET
LOOP
LOOP
LOOP
MOTOR
10
WARNING
WARNING
6' min.
Plug Reset
Switch Connector
to J5 Connector
DC-BACKUP
J5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hct 501130

Table of Contents