Solving a Mirror conflict

A Mirror conflict occurs when both disks in a RAID 1 (Mirror) configuration are
unplugged from the system in turn, then plugged in again. Since both disks contain
exactly the same data, the system will be unable to determine which of the two
is the source drive. This option allows you to set the source drive and rebuild the
Mirror drive according to the contents of the source drive.
To solve a Mirror conflict:
1.
In the main JMB363 RAID BIOS menu, highlight Solve Mirror Conflict using
the up/down arrow key then press <Enter>.
2.
Use the space bar to select the HDD that you want to set as source drive.
The selected HDD shows a
3.
Using the <TAB>, move to the RAID Disk Drive List menu and highlight the
RAID set that you want to rebuild. Press <Del> to begin rebuilding the Mirror
configuration.
A status bar at the bottom of the screen shows the progress of the rebuilding.
JMicron Technology Corp. PCI-to-SATA II/IDE RAID Controller BIOS v0.97
[Main Menu]
Create RAID Disk Drive
Delete RAID Disk Drive
Revert HDD to Non-RAID
Solve Mirror Conflict
Rebuild Mirror Drive
Save and Exit Setup
Exit Without Saving
[RAID Disk Drive List]
Members(HDDx)
RDD0: JRAID
ASUS Blitz Extreme
[Main Menu]
Create RAID Disk Drive
Delete RAID Disk Drive
Revert HDD to Non-RAID
Solve Mirror
Rebuild Mirror Drive
Save and Exit Setup
Exit Without Saving
sign before it.
[Hard Disk Drive List]
HDD0: HDS722516VLSA80
HDD1: HDS722516DLA380
Model Name
RAID Level
1-Mirror
Rebuilding... 01%, please wait...
Conflict
Model Name
Capacity
164 GB
164 GB
Capacity
Status
XXX GB
Rebuild
Type/Status
RAID Inside
RAID Inside
01
5-45

Advertisement

Table of Contents
loading

Table of Contents