Installation Instructions; Venting Requirements - Whirlpool WED6600VU - 29-in Electric Dryer Use And Care Manual

Cabrio steam fabric care system electric dryer
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION INSTRUCTIONS
Gather the required tools and parts before starting installation.
Read and follow the instructions
provided with any tools listed
here.
Flat-blade screwdriver
Tin snips (new vent
#2 Phillips screwdriver
installations)
Adjustable wrench that
Level
opens to 1" (2.5 cm) or
Vent clamps
hex-head socket wrench
(for adjusting dryer feet)
Caulking gun and
compound (for installing
Wire stripper (direct wire
new exhaust vent)
installations)
Tape measure
Parts supplied:
Remove parts package from dryer drum. Check that all parts
were included.
A
B
C
D
E
A. Leveling legs (4)
B. "Y" connector
C. Short inlet hose
D. Inlet hose with right-angle
connector
E. Rubber washer
Parts needed:
Check local codes. Check existing electrical supply and venting
and see "Electrical Requirements"
and "Venting Requirements"
before purchasing parts.
Mobile home installations require metal exhaust system hardware
available for purchase from the dealer from whom you purchased
your dryer. For information on ordering, please refer to the
"Assistance
or Service" section. You may also contact the dealer
from whom you purchased your dryer.
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with
clothes dryers. The kit should contain:
A UL listed 30-amp power supply cord, rated 120/240 volt
minimum. The cord should be type SRD or SRDT and be at
least 4 ft (1.22 m) long. The wires that connect to the dryer
must end in ring terminals or spade terminals with upturned
ends.
A UL listed strain relief.
Explosion Hazard
Keep flammable
materials
and vapors, such as
gasoline,
away from dryer,
Place dryer at least 18 inches (46 cm) above the floor
for a garage installation.
Failure to do so can result in death, explosion,
or fire.
You will need
A location that allows for proper exhaust installation. See
"Venting Requirements."
A separate 30-amp circuit.
If you are using a power supply cord, a grounded electrical
outlet located within 2 ft (61 cm) of either side of the dryer.
See "Electrical Requirements."
A sturdy floor to support the total weight (dryer and load) of
200 Ibs (90.7 kg). The combined weight of a companion
appliance should also be considered.
Cold water faucets located within 4 ft (1.2 m) of the water fill
valves, and water pressure of 20-100 psi (1 _8-690 kPa). You
may use the water supply for your washer using the "Y"
connector and short hose (if needed) which are provided.
20-100 psi (138-690 kPa) for best performance.
A level floor with a maximum slope of 1" (2.5 cm) under entire
dryer.
Do not operate your dryer at temperatures
below 45°F (7°C). At
lower temperatures,
the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes or
sleeping quarters. Contact your local building inspector.

Hide quick links: