Document T6423046-02 A01
February 2004
Figure 17 Installing the
Rear Shelf Clamps
20
7 Install the rear shelf clamps (see
Position a rear shelf clamp (PN 215201/01) on the rear left rack rail,
a
aligning the square hole with the middle insert in the shelf flange.
Verify that two of the round holes line up with holes in the rack
b
mount shelf. If two of the holes do not line up, rotate the clamp 180
degrees.
Secure the rear shelf clamp to the shelf using two M4 countersink
c
screws (PN YS42064).
Repeat these steps to install a rear shelf clamp on the rear right rack
d
rail.
The left and right rear shelf clamps will be oriented differently
Note:
from one another.
Installing a Rack Mount Library