Alevel floorwithamaximum s lope of1"(2.5 cm) u nder entire
dryer. (Ifslope isgreater than1"[2.5 cm], i nstall Extended
Dryer Feet K it, P art N o.279810.) Clothes may nottumble
properly andautomatic sensor cycles m ay notoperate
correctly ifdryer i snotlevel.
• Foragarage i nstallation,
youwillneed toplace thedryer a t
least 1 8"(46cm) a bove t hefloor. I fusing apedestal, youwill
need 18"(46cm) t othebottom ofthedryer.
Donotoperate y ourdryer a ttemperatures
below 45°F (7°C). At
lower t emperatures,
thedryer m ight n otshut o ffattheendofan
automatic cycle. D rying t imes canbeextended.
The dryer m ust n otbeinstalled orstored inanarea where i twill
beexposed towater a nd/or weather.
Check c ode requirements.
Some codes limit, o rdonotpermit,
installation ofthedryer i ngarages, closets, mobile h omes o r
sleeping quarters. Contact your l ocal b uilding i nspector.
Installation clearances
The location must be large enough to allow the dryer door to
open fully.
Dryer Dimensions
36" I
(81.4 cm)
(
*28.65"
(72.77 cm)
* Most installations require a minimum 5" (12.7 cm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Installation
spacing for recessed
area or closet installation
The following spacing dimensions
are recommended
for this
dryer. This dryer has been tested for spacing of 0" (0 cm)
clearance on the sides and rear. Recommended
spacing should
be considered for the following reasons:
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door and
floor moldings.
Additional spacing should be considered on all sides of the
dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.
Installation
spacing for custom
undercounter
installation
Custom undercounter
installation - Dryer only
--
--
2"*
36" rnin
O
,ll-il__U
j
1"'
1"'
2.Scrn
I
(68.6 cm)
2,5 crn
* Required spacing
Closet installation
- Dryer only
24 iris
_ _
(188 cm 2)
h"*_ 28.65"-_1 s"**l
(2.5 cm) (72.77cm) (12.7crn)
A
B
A. Side view - closet or confined area
B. Closet door with vents
_3"*
(7.6 crn)
f
_8"*
(7.6 crn)
7
*Required spacing
**For side or bottom venting, 0" (0 cm) spacing is allowed.
Recessed
or closet installation
- Dryer on pedestal
CO
©
*- 27"
(2.8 Cm)
(68.6 Cm)
A
IH
m..
H
II"*_ 28.68" _'1s"**l
(2.Scrn) {2.5crn) (72.77crn) {12.7crn)
B
A. Recessed area
B. Side view - closet or confined area
*Required spacing
**For side or bottom venting, 0" (0 cm) spacing is allowed.

Hide quick links:

Advertisement

Chapters

Table of Contents
loading