27 in. (69 cm) electric dryer

Advertisement

Available languages

Available languages

Electrical Connection Options
If your home has:
And you will be
Go to Section:
connecting to:
4-wire receptacle
A UL listed,
4-wire connection:
(NEMA type 14-30R)
120/240 volt
Power Supply
--j_
minimum, 30
Cord
amp., dryer
power supply
cord*
4-wire direct
A fused
4-wire connection:
disconnect
or
Direct Wire
circuit breaker
box*
3-wire receptacle
A UL listed,
3-wire connection:
(NEMA type 10-30R)
120/240 volt
Power Supply
minimum, 30
Cord
amp., dryer
power supply
cord*
3-wire direct
A fused
3-wire connection:
disconnect
or
Direct Wire
circuit breaker
box*
* If local codes do not permit the connection of a frame-
grounding
conductor to the neutral wire, go to "Optional
3-wire connection"
section.
4-wire connection:
Power supply cord
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire
connections.
2
3
4
1. Remove center terminal block screw.
2. Remove appliance ground wire (green with yellow stripes)
from external ground connector screw. Fasten it under center,
silver-colored
terminal block screw.
.............
1, External ground connector
- Dotted line shows position
of NEUTRAL ground wire before being moved to center
terminal block screw
2. Center silver-colored
terminal block screw
3. Green/yellow
wire of harness
3. Connect ground wire (green or bare) of power supply cord to
external ground conductor
screw. Tighten screw.
4. Connect neutral wire (white or center wire) of power supply
cord under center screw of the terminal block.
..................
)
I'_'
I
J
2* b
..............................................
2
6
_
1. Externalground connector
2. Green wire of power supply cord or bare copper wire
3. _ in. (1.9 cm) UL-listed strain relief
_
4. Center silver-colored terminal block screw
5. Neutral wire (white or center wire)
5
7
6. Neutral grounding wire (green/yellow)
1.4-wire
receptacle
(NEMA type 14-30R)
2. 4-prong plug
3. Ground prong
4. Neutral prong
5. Spade terminals with upturned
ends
6. _ in. (1.9 cm) UL approved strain relief
7. Ring terminals
5. Connect the other wires to outer terminal block screws.
Tighten screws.
6. Tighten strain relief screws.
7. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.