Factory Reset; Installation Cycle; Diagnostic Mode - Electrolux EIED55HIW - 8.0 cu. Ft. Electric Dryer Wiring Diagram

Wiring diagram (all languages)
Hide thumbs Also See for EIED55HIW - 8.0 cu. Ft. Electric Dryer:
Table of Contents

Advertisement

Available languages

Available languages

Error
Fault
Code
Outlet Control
Thermistor open
E71
circuit
Outlet Control
E72
Thermistor short
circuit
E73
Inlet Control
Thermistor open
circuit
Inlet Control
E74
Thermistor short
circuit
Communication
E91
Error
Incompatible
Electronic Control Board incompatible
E92
protocol
Machine
E93
configuration
Interface Board or Electronic Control
checksum error
Cycle configuration
Wrong configuration data loaded or
E94
checksum error
E97
Program mismatch
Main Supply
EA1
Frequency out of
Range
Voltage too high
EA2
EA3
Voltage too low
Improper home
EA4
wiring
Main V Sensing
EA5
failure
High vent restriction, Exhaust Control
EF1
Vent Blocked
Thermistor, Inlet Control Thermistor, or
EF3
Max Timeout Timer
EF8
Key Stuck

FACTORY RESET

1. Press and hold the "Temperature" and "Dryness" buttons simultaneously for 6 seconds.

INSTALLATION CYCLE

1. Use the selector knob to select the "touch up" cycle
2. Press and hold the "my favorite" and "sanitize" buttons simultaneously for 6 seconds.
3. Remove any load from the dryer and press "start pause" to start installation cycle.

DIAGNOSTIC MODE

1. Press the "cancel" button to enter standby mode and enable diagnostic entry.
2. Within 10 seconds after pressing "cancel", press any button (but "cancel") to wake up the control.
3. Within 5 seconds of wake up, turn the selector knob to the far left cycle and press and hold the "cancel" and the far left
button under the display simultaneously for 3 seconds to enter the Diagnostic Mode. (note: to save time at wake up,
the welcome screen can be bypassed by turning the selector knob).
4. Upon entering Diagnostic Mode, all lights should flash on and off.
5. The following steps can be cycled through by turning the selector knob clockwise:
Possible Fault Conditions
Outlet Control Thermistor or wiring
defective
Outlet Control Thermistor or wiring
defective
Inlet Control Thermistor or wiring
defective
Inlet Control Thermistor or wiring
defective
Wiring, Electronic Control Board, or
Interface Board defective
with Interface Board
Wrong configuration data loaded,
Board or wiring defective
Electronic Control Board defective
Wrong configuration data loaded,
Electronic Control Board defective
Line frequency out of limits or
Electronic Control Board faulty
Line voltage too high or Electronic
Control Board faulty
Line voltage too low or Electronic
Control Board faulty
Line connections in home faulty,
wiring or Electronic Control Board
defective
Electronic Control Board defective
Electronic Control Board defective
Exhaust blocked; Exhaust Control
Thermistor, Inlet Control
Thermistor, Contact Sensor or
Electronic Control Board defective
Console button or Interface Board
defective
Possible Solutions
Check resistance of Outlet Control Thermistor, and check wiring for open circuit.
Resistance should be between 4.9K Ohm and 6.2K Ohm at room temperature
(68-77° F or 20-25° C). Replace Outlet Control Thermistor and/or wiring and
Check resistance of Outlet Control Thermistor, and check wiring for short circuit
across Thermistor connections. Resistance should be between 4.9K Ohm and
6.2K Ohm at room temperature (68-77° F or 20-25° C). Replace Outlet Control
Thermistor and/or wiring and retest.
Check resistance of Inlet Control Thermistor, and check wiring for open circuit.
Resistance should be between 47K Ohm and 66K Ohm at room temperature
(68-77° F or 20-25° C). Replace Inlet Control Thermistor and/or wiring and
Check resistance of Inlet Control Thermistor, and check wiring for short circuit
across Thermistor connections. Resistance should be between 47K Ohm and
66K Ohm at room temperature (68-77° F or 20-25° C). Replace Inlet Control
Thermistor and/or wiring and retest.
Check connections between Electronic Control Board and Interface Board. If no
wiring problems, replace Electronic Control Board or Interface Board.
Check if correct Interface Board console and Electronic Control Board are
installed. Replace appropriate hardware.
Check if correct Interface Board and console are installed. Replace Interface
Board and/or console.
Replace Electronic Control Board.
Replace Electronic Control Board.
Check frequency of line voltage.
Check amplitude of line voltage.
Check amplitude of line voltage.
Check wiring at terminal block for L1-N-L2 wired incorrectly.
Replace Electronic Control Board.
Check vent restrictions and resistance values of Exhaust Control Thermistor
and Inlet Control Thermistor.
Check vent restriction, Contact Sensor, and resistance values of Exhaust
Control Thermistor and Inlet Control Thermistor
Check buttons for activation when pressed. Replace console or Interface Board
2
retest.
retest.
as appropriate

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents