MAINTENANCE

Maintenance intervals and normal parts replacement vary widely depending on numerous factors such as: type of
vessel, frequency of system use, quality of flushing water, etc. The chart below is intended strictly as a general
guideline. Owner discretion and consideration of actual usage must be the first basis for determining proper
maintenance levels.
Maintenance Procedure
Follow cleaning procedures above.
Tighten all clamps, including base clamp ring.*
Check all wire connections.
Check & tighten water valve mounting screws.
Clean filter screen in water valve.
Check pump and in-line valves.
Check toilet seals.
Check vacuum breaker.
Check water valve.
*See Base Assembly - Page 7.

ORDERING PARTS

Dometic is ready to assist you in the event service is required. Before calling, please have the following information
available. Your cooperation in having this information ready is appreciated and allows our Customer Service
Department to better meet your needs. When you call, we will direct you to the nearest stocking parts distributor.
1. Toilet Model Number
2. Serial Number
3. Part Number, Description and Quantity (See Parts Lists for information.)

VACUUM TESTER

Dometic has developed a simple tool to assist in
identifying the location of vacuum leaks. The vacuum
tester consists of a vacuum gauge and a cone-shaped
plug. Inserting the plug in the inlet of the vacuum
tank or generator isolates the toilet from the
system. In this way a troublesome leak can easily
be located in either system.
Order only the Vacuum Tester (Part Number 530002)
or as part of the complete system maintenance kit
(Part Number 310228).

SERVICE TIP

Checking for leaks behind or under toilets or other appliances can make it difficult to locate the source. Dripping
water at room temperature makes it difficult to feel wetness. Taking four or five sheets of toilet tissue and wiping all
seams and waterline connections offers a simple means of locating the general area of the leakage. Start at the top
of the unit since gravity will cause a leak to run downward. When the tissue comes in contact with the leaking
water, it will immediately change texture.
Part Number
Approximate Maintenance Level
347802
316140
316906
314349
6
Monthly
Annually
Annually
Annually
Annually
2-3 years or as needed
3-5 years or as needed
3-5 years or as needed
3-5 years or as needed
Vacuum Tester