6.3
Changing "Flush" modes
MasterFlush7640 toilets offer two flush settings to help manage water
consumption:
 Normal flush – Uses 0.83 gal. (3.1 l) per flush. Adds water to bowl after
every flush.
 Dry Bowl flush – Uses 0.21 gal. (0.79 l) per flush. Does not add water to
bowl after flush.
1.
To change from Normal to Dry Bowl flush setting, press flush pedal for
about 10 seconds.
✓ Flush mode has been changed to Dry Bowl setting.
2.
Change mode to Normal flush by following the same procedure.
7

Maintenance and winterizing

7.1
Routine toilet cleaning
For routine cleaning, use Dometic Toilet Bowl Cleaner. If this cleaner cannot
be found in your area, contact the manufacturer for your nearest dealer (see
the back of the manual for the addresses). If the cleaner is not available, use
most any nonabrasive bathroom and toilet bowl cleaner. Please follow label
instructions.
!
CAUTION!
To avoid damaging internal seals, do not clean toilet with abrasive
cleaners, caustic chemicals, or lubricants and cleaners that
contain alcohols or petroleum distillates.