Cylinder Head Assembly - Eton CXL-150 Service Manual

Table of Contents

Advertisement

Inspect each valve for turning, burning, scratches
or abnormal stems wear.
Check the valve movement in the guide.
Measure and record each valve stem O.D.
SERVICE LIMITS: 4.90 mm
Measure and record the valve guide I.D.
SERVICE LIMITS: IN / EX 5.30 mm
Calculate the stem-to-guide clearance.
SERVICE LIMITS: IN 0.08 mm
NOTE: If the stem-to-guide clearance exceeds
the service limits, determine if a new
guide with standard dimensions would
bring the clearance within tolerance.
If so, replace guides as necessary and
ream to fit. If the valve guide is replaced,
the valve guide is replaced; the valve
seat must be refaced.

CYLINDER HEAD ASSEMBLY

Lubricate each valve stem with oil.
Insert the valves into guides.
Install the valve springs, retainers and the cotters.
NOTE: To prevent loss of tension, don't
compress the valve springs more than
necessary.
EX 0.10 mm
INLET VALVE
22
EXHAUST VALVE

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Exl-150 viperRxl-150Yxl-150Exl 150 2004

Table of Contents