Low Speech Volume at the Entry Panel
1. Volume adjustment required on the Entry Panel.
2. Entry Panel grill is blocked
3. Entry Panel or Intercom/Phone supply voltage is low (Minimum of 15V DC required)
No speech when the Intercom/Phone is buzzed
1. Wiring fault on the speech signal connections R or T. R carries the audio from the
Intercom/Phone to the Entry Panel. T carries audio from the Entry Panel to the
Intercom/Phone.
Intercom/Phone will not buzz
1. Faulty 0V or CALL line between power supply and phone. Check for a voltage level
between 13V and 15V, between CALL and 0V, when CALL button pressed.
Intercom/Phone Release button does not operate relay
1. Fault on DOOR1 / I or 0V line. Check that it goes to 0V when Button 1 on the intercom
is pressed.