IBM 8687 - Eserver xSeries 440 Planning And Installation Manual page 149

Installation guide
Table of Contents

Advertisement

Message
Meaning
Surprise removal
Operating system activity to slot
occurred
was not stopped before power to
adapter was removed.
Slot disabled at
A second 133 MHz adapter was
current speed
hot-added to a two-slot bus that
already had a 133 MHz adapter
installed. The new adapter is held
inoperative.
Too many adapters on
Two PCI-X 133 MHz adapters in a
bus
slot pair.
Bus connection error
System has detected a hardware
fault.
The tree view, shown in Figure 5-5, lets you look at all of the slots in the system
at once, in a Explorer-like tree view.
Figure 5-5 x440 and RXE-100 tree view
In Figure 5-5, the x440 slot 2 is selected and the attributes of the slot and the
adapter installed in it are shown on the right. For information about the attributes,
see the discussion following Figure 5-4 on page 133 and the online help.
Recommended Action
This should be avoided. Use the Unplug
or Eject Hardware wizard to disable the
adapter before removing it.
Restart the server. The bus will run at 100
MHz and both adapters will be operative.
Move one of the adapters to an empty
bus.
Remove the adapter. If this does not
correct the condition, have system
serviced.
Chapter 5. Management
135