38
MP2 - Limit values
Set max. sewing speed
(min. = 500 .. max. 3000; def. 3000 U/min)
Limitation of all sewing programs to this speed.
Set max. run empty speed
(min. = 10 .. max. 100; def. 100%)
Limitation of all clamp movements between seam
to this value.
Set feeding start
(min. = 30 .. max. 350; def. 180 degrees)
At this angle of needle movement the clamp starts
to move during the stitch.
Set feeding phase
(min. = 30 .. max. 100; def. 80%)
This parameter determines how the clamp movement
takes place during the stitch. (At 100% the requested
clamp movement is equally divided over the
whole stitch).
Set needle reversing position
(min. = 0 .. max. 359; def. 0 degrees)
The needle will be turned back to this angle in order
to enlarge the distance to the clamp.
Editing timings distances
This function is reserved for the Dürkopp-Adler service
personnel.
MP3 - Needle thread monitor
Upper thread monitor mode
The following modes are available:
Threading position (def.)
After detecting thread breakage the thread will be
trimmed and the clamp will then go to the threading
position.
Thread cutting
After detecting thread breakage the thread will be
trimmed and the clamp moves according to the
set reverse drive to the contour position.
Pausing
After detecting thread breakage the sewing movement
will be stopped.
Not activated
The needle thread monitor is ignored.