Download Print this page

DURKOPP ADLER DAC BASIC - CLASS 271 MANUAL PART II V 12-2010 Operating Manual page 10

Hide thumbs Also See for DAC BASIC - CLASS 271 MANUAL PART II V 12-2010:

Advertisement

Operating manual part II
L
C
P
Min
Thread tension
t
09
00
0
t
09
01
0
t
09
02
0,0
t
09
10
0
t
09
11
0
t
09
20
0
t
09
21
0
t
09
50
0
t
09
51
5
t
09
52
0,0
t
09
53
5
t
09
54
0
High lift for walking foot
t
10
00
0
t
10
01
0
t
10
02
1
t
10
03
1
t
10
04
-
t
10
05
0
Max
Preset Unity
3
0
°
1
1
°
2,55
0,0
s
359
50
°
359
306
°
255
0
ms
255
40
ms
999
80
ms
100
100
%
600,0
60,0
s
100
70
%
1
0
-
1
0
-
9999
1800
rpm
21
10
Step
21
19
Step
-
-
-
1
0
-
Description
Mode of the thread tension release and thread tension
reduction with active foot lifting.
0 = No thread tension release;
1 = Thread tension release in the seam;
2 = Thread tension release after thread trimming;
3 = Thread tension release in the seam and after thread
trimming.
Thread tension release by thread he lp
0 = No;
1 = Yes
Delay time of the tread tension release after thread trimming.
(Only active if t 09 00 = 2 or 3)
on switching angle t 08 of 12 < = t of 09 10 < t 09 11 at the
trimming process
off switching angle t of 09 10 < t 09 of 11 < = t 08 13 at the
trimming process
Delay time for a repeated activation of the tension magnet at
the trimming process.
Delay time for turning the tension magnet off at the trimming
process
Drive time of the thread tension magnet in the time period t
Pulse duty ratio in the time period t
Drive time of the thread tension magnet in the time period t
(If you adjust 0s the thread tension magnet will be driven
permanently)
Pulse duty ratio in the time period t
Increasing U
when the thread tension magnet will be driven
mag
0 = No;
1 = Yes
High lift for walking foot
0 = No;
1 = Yes
High lift walking speed
Lower speed break point
Upper speed break point
Show the actual position of the potentiometer and the actual
limitation of the speed
3: 2800
3: = actual position
2800 = speed limitation
Operational mode of the high lift for walking foot
0 = not stored;
1 = stored