For systems using multiple partitions/areas, access codes can be assigned to specific or multiple partitions/areas.
Please contact your alarm company for details.
The minimum number of variations of access codes (key) is 27027 when 37, 6-digit user codes are used. For SIA
Installations, duplicate or duress codes derived from user codes +/- 1 digit are not allowed.
The access codes have programmable attributes which allow zone bypassing, remote access using the
ESCORT5580TC or one-time use activation.

Access Codes

[
][5][Master Code] (when disarmed)
,
,
The [
][5] User's Programming command is used to program additional access codes.
User Codes (Access Codes 1-32)
Master Code (Access Code 40)
Supervisor Codes (Access Codes 41 & 42)
Programming section. However, these codes can only program additional codes which have equal or lesser
attributes. Once programmed, the Supervisor Codes receive the Master Code's attributes. These attributes are
changeable.
Duress Codes (Access Codes 33 & 34)
Duress Reporting Code whenever the code is entered to perform any function on the system.
NOTE: Duress codes are not valid when entering [
NOTE: No codes can be programmed as a duplicate of another code.
NOTE: Duress codes cannot be programmed as a duplicate or as a "Code + 1".

User Code Attributes

1. The default attributes of a new code will be the attributes of the code used to enter
code or an existing code being programmed.
2. System Master (Code 40) has Partition Access for all partitions, as well as Attributes 3-4 ON by default.
NOTE: These attributes are not changeable.
Inherent Attributes (all codes except installer and maintenance)
- Any Access Code with Partition Access enabled will be valid for arming and disarming that partition.
Arm / Disarm
,
Command Outputs ([
Access Code with Partition Access will be valid for performing the [
tion.
Programmable Attributes ([
1. For Future Use
2. For Future Use
3. Zone Bypassing Enabled
4. ESCORT Access
5. Downlook Remote Trigger to Phone Number 1
6. Downlook Remote Trigger to Phone Number 2
7. Bell Squawk upon Arming/Disarming
8. One Time Use Code
NOTE: Attributes 5 and 6 cannot be enabled on the same access code.
- The Master Code can only be changed by the Installer, if programmed.
- These codes are always valid when entering the
- Duress codes 33 and 34 are standard User Codes that will transmit the
,
,
][7][1], [
][7][2], [
][7][3], and [
,
][5][Master/Supervisor Code][9][Code])
,
][5], [
,
][6] or [
,
][8] sections.
,
- If these outputs require Access Code entry, any
][7][4])
,
][7][1-4][Access Code] functions on that parti-
12
User Code
whether it is a new

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents