e. Pull out the microprocessor tray until it stops; then, push in on the
microprocessor tray retention latches on each side of the tray and pull the
tray out of the server.
Attention:
The microprocessor tray is heavy. Pull the tray partially out of
the server, reposition your hands to grasp the body of the tray, and press
in on the release latches on each side of the tray; then, pull the tray out
the rest of the way.
Air baffle
Note: The new microprocessor comes in a kit with a VRM and a heat sink.
The VRM is used only with a microprocessor that is installed in socket 3 or 4.
4. Lift the air baffle out of the microprocessor tray.
5. Remove the microprocessor baffle from a microprocessor socket and store it
for future use.
6. Remove the protective cover, tape, or label from the surface of the
microprocessor socket, if any is present.
7. Lift the microprocessor-release lever to the fully open position (approximately
135° angle).
Heat sink
Microprocessor
Microprocessor
baffle
VRM 4
Chapter 2. Installing options