The following notes describe the types of drives that the server supports and other
information that you must consider when installing a hard disk drive:
v Make sure that you have all the cables and other equipment that is specified in
v Check the instructions that come with the drive to see whether you must set any
v Diskette drives, tape drives, CD-ROM, CD-RW, and DVD drives are examples of
v The integrated IDE controller in the server supports up to two IDE devices.
v You can install a 3.5-in. slim-high or 5.25-in. half-high removable-media drive,
v The server supports only one diskette drive.
v To install a 3.5-in. drive in a 5.25-in. bay, you must use the 5.25-in. conversion
v The electromagnetic interference (EMI) integrity and cooling of the server are
v For a complete list of supported options for the server, go to

Installing a drive in bay 2

Complete the following steps to install a drive in bay 2:
38
xSeries 226 Type 8488 and 8648: Hardware Maintenance Manual and Troubleshooting Guide
the documentation that comes with the drive.
switches or jumpers on the drive. If you are installing a SCSI device, be sure to
set the SCSI ID for that device.
removable-media drives. You can install removable-media drives in bays 1, 2,
and 3 only.
such as a tape backup drive, CD-RW drive, or DVD drive, in bay 2.
kit. Contact IBM to order the conversion kit.
protected by having all bays and PCI slots covered or occupied. When you install
a drive or PCI adapter, save the EMC shield and filler panel from the bay or the
PCI adapter slot cover in the event you later remove the option.
http://www.ibm.com/pc/support/.
1. Read Appendix B, "Safety information," on page 143, and the "Installation
guidelines" on page 25.
2. Turn off the server and peripheral devices, and disconnect the power cords
and all external cables.
3. Remove the side cover (see "Removing the side cover" on page 28).
4. Remove the support bracket (see "Removing and installing the support
bracket" on page 32).
5. Remove the bezel (see "Removing the bezel" on page 30).
6. Use a screwdriver to pry the filler panel and EMC shield away from the server.
Note: If you are installing a drive that contains a laser, observe the following
safety precaution.