Electrical connections

DANGER
Danger of electric shock! All fittings must be
installed by a competent person in accordance
with current wiring regulations and local
building regulations. If in doubt, consult a
qualified electrician.
IMPORTANT
Always switch off the electricity supply at
the mains during installation, cleaning and
maintenance. We recommend that the fuse is
withdrawn or circuit breaker switched off at the
distribution board while work is in progress.
Step 5:
• Loosen the 2 short screws from the junction box
(fig.
).
fig.
fig.
• Connect the incoming positive, neutral and
ground cables to the respective terminals. The
ground cable is already pre-assembled onto the
junction box to provide grounding (fig.
Installing the hood
fig.
fig.
fig.
• Mount the junction box onto the range hood
using 2 short screws (15) (fig.
Step 6:
• Insert the upper chimney (3) into the lower chimney
(3) from top to bottom (fig.
• Mount upper and lower chimney (3) on the range
hood (1). Fit the tab, which is bend by 90 degrees,
into the lower bracket notch and mount to the lower
bracket (5) (fig.
• Pull the upper chimney (3) to the upward position to
match the screw hole of the upper bracket. Mount to
the upper bracket (4) with 2 side screws (12) (fig. ).
fig.
fig.
fig.
).
L (live) = Black
N (neutral) = White
(ground) = Green
L
N
).
fig.
).
/
).
fig.
fig.
fig.