  • Page 1: Instruction Manual

    BODY COMPOSITION ANALYZER SC-330ST Instruction manual REMOTE DISPLAY VERSION COLUMN MOUNTED VERSION Please read this Instruction Manual carefully and keep it handy for future reference.
  • Page 2: Table Of Contents

    Table of Contents Before use Safety Notes •••••••••••••••••••••••••••••••••••••••••••• Product Assembly and Components •••••••••••••• Preparation ••••••••••••••••••••••••••••••••••••••••••••• Various settings •••••••••••••••••••••••••••••••••••••• How to use Operating Instructions ••••••• When using as a body composition analyzer •• Target body fat ratio •••••••••••••••••••••••••••••••• When using as a scale ••••••••••••••••••••••••••••••...
  • Page 4: Product Assembly And Components

    Product Assembly and Components Remote display version Column mounted version Control Box Accessories Accessories Printer cover Instruction manual (This manual) Instruction manual (This manual) AC adapter Assembling guide Power cord AC adapter Power cord Control Box Dropper (1 item) Hexagonal wrench (1 item) Hexagon socket head bolts (M5L12) (4 items) Display...
  • Page 5: Preparation

    Preparation Setting of the printer paper • Please change the paper roll when red lines appear along the sides of the paper. Control panel • Please pay careful attention to avoid injury from the sharp edge. • Please turn off the machine before clearing Paper jams. Setting of the printer paper Press to turn on the power.
  • Page 6: Various Settings

    Setting items Print item setting ON / OFF Press Set Up Date and time( page 12) TANITA Logo ( page 22) • The setting item input screen is displayed. Category name ( page 22) Number of sheets to print • 39 – 64 are the setting items related to print out items...
  • Page 7 Various settings Setting methods (continued) Register the date and time Set the number of sheets to print for the body composition Analyzer (Continued from page 10). (Continued from page 10). Press and then press Press and then press Enter / Next Enter / Next •...
  • Page 8 Various settings Setting methods (continued) * Invalid in st.lb mode. Set ON / OFF of the automatic cutting of the printer paper Set ON / OFF of the Fat % Healthy range display (Continued from page 10). (Continued from page 10). Press and then press Press...
  • Page 9 Various settings Setting methods (continued) * Invalid in st.lb mode. Select the measurement flow Set the input unit of height (Continued from page 10). (Continued from page 10). Press and then press Press and then press Enter / Next • The “ON or OFF of the one step mode” selection screen is Enter / Next displayed.
  • Page 10 Various settings Setting methods (continued) Set ON / OFF of the target body fat ratio Set the print item preset (Continued from page 10). (Continued from page 10). Press and then press Press and then press Enter / Next Enter / Next •...
  • Page 11 17 years old or younger are for reference. Please consult your doctor before you start a body weight management program. Tanita is not responsible *18 - 99 yaers only for the target body fat ratio.
  • Page 12 (Continued from page 10). Select the number to set with the Print item setting ON / OFF <In the case of selecting 39> numeric keys ( – TANITA Logo Metabolic age Category name Visceral fat rating and press Enter / Next...
  • Page 13: Operating Instructions

    Operating Instructions when using as a body composition analyzer This explains the procedure when the printer is turned on. Please be aware that the display may be Check that the body different if the number of sheets to print is set to composition is selected and •...
  • Page 14: When Using As A Body Composition Analyzer

    Operating Instructions when using as a body composition analyzer(continued) Step on the electrodes with bare <Child> <Adult> Press Enter / Next feet. Note Take off your socks and stockings before stepping on. • This screen is not displayed if OFF is set in the “setting with or without an ID”...
  • Page 15 Operating Instructions when using as a body composition analyzer(continued) Input the age. Measurement completion The measurement result and the body fat percentage Input it by pressing – evaluation are displayed. It is automatically printed out. (In the case that other Note than 0 is set in the “Setting the number of sheets to •...
  • Page 16 Operating Instructions when using as a body composition analyzer(continued) Input the ID number. In the case of the one step mode Input it by pressing In the one step mode, after inputting the personal data, the weight and body composition are measured. Note Personal data input Weight measurement...
  • Page 17 Operating Instructions when using as a body composition analyzer(continued) Input the age. Step on the electrodes with bare feet. Input it by pressing – Take off your socks and stockings before stepping on. Note • The age can be input from 5 – 99. •...
  • Page 18: Target Body Fat Ratio

    Before you start a body weight management program and set the appropriate personal Note body fat ratio, please consult your doctor. Tanita is not responsible for setting the • The clothes weight (preset tare) can be input in the appropriate target body fat ratio for specific individuals.
  • Page 19 Operating Instructions when using as a scale (continued) Input an ID number. Measurement completion It is automatically printed out. (In the case that other Input it by pressing – than 0 is set in the “Setting the number of sheets to print”...
  • Page 20: Various Criteria

    2 diabetes. (-) : Underfat; below the healthy body fat range. Increased risk for health The Tanita Body Composition Analyzer will provide you with a visceral fat rating from 1 – 59. problems.
  • Page 21 The basic way of calculating Basal Metabolic Rate BMR is a standard equation using weight and age. Tanita has conducted in-depth research into the relationship of BMR and body composition giving a much more accurate and personalized reading for the user based on the impedance measurement. This method has been medically validated using indirect calorimetry (measuring the breath composition).*...
  • Page 22: Troubleshooting

    Troubleshooting - Please check the following before asking for repair. Symptom Please check Symptom Please check Impedance Run out of print paper measurement error •Print paper is not supplied. e Supply paper. e In the case that the printer is not used, press •Measure with bare feet.
  • Page 23: Connection With A Personal Computer

    Connection with a personal computer - Connection Example The RS-232C interface enables input and output from this equipment. This equipment is not capable of being remotely controlled by external equipment, such as a computer. Please be sure to use a straight cable when the equipment is connected to an external computer. - Specifications Communication standards Compatible with EIA RS-232C...
  • Page 24 - Transmit data (2) Output data items Transmission Data is output immediately after measurement regardless of the status of Order of output the receiving equipment (personal computer, etc.). Therefore the receiving equipment Item Header Format Contents Body composition analyzer Scale needs to be ready to accept the data before measuring.
  • Page 25: Technical Notes

    The Tanita Body Composition Analyzer measures body composition using a constant current source with a high frequency current (50kHz, 90µA). The 8 electrodes are positioned so that electric current is supplied from the electrodes on the tips of the toes of both feet, and voltage is measured on the heel of both feet.
  • Page 26 These inter-day changes stem from such causes as: - Factors giving errors in measurement 1) Temporary increases in body weight (total body water) through overeating and overdrinking 2) Dehydration due to heavy sweating during vigorous exercise In the BIA method, impedance is measured and the body composition is calculated based on the value. It 3) Dehydration due to alcohol consumption or the use of diuretics is known that impedance changes by the amount of the total body water that occupies about 60% of 4) Dehydration due to heavy sweating during saunas, etc.
  • Page 27: The New Regression Formula For Basal

    First Annual Nutrition Week (American College of Nutrition, American Society for Clinical Nutrition, Currently, the BMR estimation recursion formula developed by Tanita, the manufacturer of body American Society for Parenteral and Enteral Nutrition, North American Association for the Study of composition analyzers, based on their research, works by multiple regressive analysis using this FFM, and Obesity) held in 2002 in San Diego.
  • Page 28: Specifications

    3 ft - 7 ft 11.5 in / 0.5 in increments Measurement Frequency 50 kHz FAT% 3 - 75% / 0.1% increments Measurement Current 90 µA Logo TANITA LOGO (240x64 dot) Impedance Electrode Material Pressure Contact Stainless Steel Foot Pads Model Name SC-330ST Measurement Measurement Style...
  • Page 29 Copyright © 2008 TANITA Corporation. All Rights Reserved. SC3307651...