IV.
FOR AREA OR ROOM OPERATION
1. Place the UV-1500C in the desired area; plug the power cord into a standard
120-volt wall receptacle.
2. Turn the speed control knob clockwise to turn on the unit and to adjust the
motor/fan speed to the desired airflow. (See Figure 1)
3. After the fan has started, the LED light will show a continuous "GREEN" color
indicating proper unit operation.

WALL MOUNTING OPTION

V.
the unit to be mounted onto a wall)
1. To install the mounting brackets, remove the eight mounting screws from the back of the UV-1500C shown in
Figure 2.
2. Install the four mounting brackets onto the back of the housing securing them with the mounting screws you just
removed. (See Figure 3)
3. Determine the desired location on the wall (a 120-volt wall receptacle should be within 5 feet of the unit) and mark
the mounting screw locations based on the dimensions given in figure 4A.
4. Install four drywall anchors or other appropriate fasteners rated for at least a 15 lbs load capacity. (See Figure 4B)
5. Mount the unit to the wall. (See Figure 5)
6. Plug the power cord into a standard 120-volt wall receptacle. Turn the speed control knob clockwise to turn on
the unit and adjust the motor/fan speed control to the desired airflow.
7. After the fan has started the LED light will show a continuous "GREEN" color indicating proper unit operation.
Mounting
Screws
Figure 2
VI.
SUSPENSION OR DROP CEILING OPTION
The UV-1500C must be wired in accordance with the National Electrical Code and any applicable local codes. The
UV-1500C must be hard-wired using metal-shielded cable, BX cable or other similar wiring methods.
1. Install the four mounting brackets onto the back of the housing securing them with the
eight mounting screws (See Figure 2 & 3).
2. Mount the supplied drop ceiling body extension covers onto the sides of the UV-1500C.
These covers allow the UV-1500C to fit into a standard 2 foot by 2 foot ceiling tile space
(23-3/4"). Align the edges of the extension cover to the front of the UV-1500C body and
use the holes in the cover as a template to mark the mounting hole locations on the UV-
1500C body. (See Figure 7)
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or
blindness. Never operate the UV-Aire™ Air Purifying System with the UV chamber door open. Avoid touching the glass portion of the