Upgrading the Memory
Remove the chassis cover by unscrewing the screw on the front of the cover and sliding the cover straight
Step 6
back.
Step 7
Locate the DIMM sockets and select the empty DIMM socket next to the existing DIMM.
Note
Locate the ejector tabs on either side of the DIMM socket. Press down and out on tabs to open the slot
Step 8
in the socket.
Install the new DIMM, by positioning the DIMM into the socket and pressing it into place.
Step 9
Note
Replace the chassis cover and reconnect the power.
Step 10
Power on the sensor and make sure the new memory total is correct.
Step 11
Note
Installing Cisco Intrusion Prevention System Appliances and Modules 5.1
2-4
The existing DIMM is installed in socket 0. The angled position of the DIMM sockets make
installing an additional DIMM in socket 1 difficult if a DIMM occupies socket 0. Therefore, you
should first remove the existing DIMM from socket 0, place the new DIMM in socket 1, and then
replace the existing DIMM in socket 0.
DIMM
Do not force the DIMM into the socket. Alignment keys on the DIMM ensure that it only fits in
the socket one way. If you need additional leverage, you can gently press down on the DIMM
with your thumbs while pulling up on the ejector tabs.
If the memory total does not reflect the added DIMMs, repeat Steps 1 through 4 to ensure the
DIMMs are seated correctly in the socket.
Chapter 2
Installing IDS-4210
OL-8677-01