Push-To-Start Relay Operation - Maytag Neptune MAH3000 Service Manual

Neptune series 27" front-load washer
Hide thumbs Also See for Neptune MAH3000:
Table of Contents

Advertisement

The following rules determine the maximum
number of redistribution attempts that will be
allowed in each spin step before the machine
control skips the step and continues with the
spin profile (See Section 2: Unbalance Con-
trol System).

Push-To-Start Relay Operation

STARTING THE WASHER
1. With the door closed, press the push-to
start switch.
2. The red no. 28 wire sends a signal to the
machine control to start running.
3. 120 VAC is supplied to the machine con-
trol board through black wire no. 27.
4. The machine control closes an internal
switch to energize the line relay.
5. When the push-to-start button is released,
power remains supplied to the machine
control and the washer from gray wire
no. 26 through the line relay.
MACHINE CONTROL BOARD
120 VAC LINE
(W hen door is
closed)
Figure 1-8
16008373-01
LINE
RELAY
NO
C O M
GY 26
BK 27
PUSH TO START SWITCH
© 1998 Maytag Corporation
STOPPING THE WASHER
1. With the washer running, power is
supplied to the machine control and
washer from gray wire no. 26 through the
line relay.
2. When the user presses the push-to-start
button, a signal is sent to the machine con-
trol through red wire no. 28 telling the
washer to shut down.
3. The machine control opens the internal
logic switch which de-energizes the line
relay.
4.
When the user releases the push-to-start
button, power is removed from the ma-
chine control and washer (Black wire no.
27).
INTERNAL LOGIC
SWITCH
120 VAC POWER
FROM MACHINE
CONTROL BOARD
120 VAC Line
To Timer &
Motor Control Board
SECTION 1. GENERAL INFORMATION
RD 28
1-12