ProCon
— D750 Series
®
Conductivity Controller
Quick Start Manual
Read the user's manual carefully before starting to use the unit.
Producer reserves the right to implement changes without prior notice.
1
24-0523 © Icon Process Controls Ltd.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ProCon D750 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for ICON ProCon D750 Series

  • Page 1 ProCon — D750 Series ® Conductivity Controller Quick Start Manual Read the user's manual carefully before starting to use the unit. Producer reserves the right to implement changes without prior notice. 24-0523 © Icon Process Controls Ltd.
  • Page 2: Technical Specifications

    No strong magnetic field interference around except the geomagnetic field Working Temperature 14 ~ 140 F | -10~60°C Relative Humidity ≤90% Waterproof Rating IP65 Dimensions 144 x 114 x 118mm Mounting Panel | Wall Mount 24-0523 © Icon Process Controls Ltd.
  • Page 3 ProCon — D750 Series ® Conductivity Controller Dimensions 118mm 144mm 26mm M4x4 45x45mm 138mm +0.5mm Back Fixed Hole Size Embedded Mounting Cut-out Size 24-0523 © Icon Process Controls Ltd.
  • Page 4: Embedded Installation

    Schematic of Completion of Installation Wall Mount Installation 150.3mm 6x1.5mm Schematic of Completion of Installation a) Install a mounting bracket for the instrument b) Wall screw fixation Top view of mounting bracket Pay attention of installation direction 24-0523 © Icon Process Controls Ltd.
  • Page 5 5-10 Meters, insert the line with corresponding label or color wire on the sensor into the corresponding terminal inside the instrument and tighten it. 24-0523 © Icon Process Controls Ltd.
  • Page 6: Keypad Description

    Long Press: Long Press is to press the button for 3 seconds and then release it. Press & Hold: Press and hold means to press the button, and accelerate after a certain time until the data is adjusted to the user's required value before releasing the button 24-0523 © Icon Process Controls Ltd.
  • Page 7: Display Descriptions

    History °C System Electromagnetic Conductivity Meter Electromagnetic Conductivity Meter Calibration Mode Trend Chart Display 2024-02-12 12:53:17 2024-02-12 12:53:17 001644:001644 2019-01-09 12:53:17 7.850 NTU Point 1 Voltage: 0.000 Calibrating Electromagnetic Conductivity Meter Electromagnetic Conductivity Meter 24-0523 © Icon Process Controls Ltd.
  • Page 8: Menu Structure

    10.0 (Default, can be modified) Description Point 5 20.0 (Default, can be modified) Standard Solution Voltage 1 Calibration Calibration Voltage 2 Calibration Voltage 3 Adjustment Voltage 4 Voltage 5 Field Calibration Field Calibration Offset Adjustment Slope Adjustment 24-0523 © Icon Process Controls Ltd.
  • Page 9 (Off Time - In Cleaning State) Main Channel Temperature 4-20mA Description Output Option 0-20mA Current 1 20-4mA Upper Limit Lower Limit Output Main Channel Temperature 4-20mA Description Output Option 0-20mA Current 2 20-4mA Upper Limit Lower Limit 24-0523 © Icon Process Controls Ltd.
  • Page 10 Memory Information 101600 Point Data Output Language English Year-Month-Day Date/Time Hour-Minute-Second Standard Display Speed Medium High Saving Description System Backlight Display Bright Range Set Automatic Software Version 1.9-1.0 Software version Password Settings 0000 Serial number 24-0523 © Icon Process Controls Ltd.
  • Page 11 If the monitor prompts you to enter the calibration safety password, press [ ] or [ ] key to set the calibration safety password, then press [ENT] to confirm the calibration safety password. 24-0523 © Icon Process Controls Ltd.
  • Page 12: Field Calibration

    Compare the data from portable instrument with the data measured by isntrument. if there is any error, the error data can be modified by this function. Linear adjustment Linear values after "field calibration" will be saved in this term and the factory data is 1.00. 24-0523 © Icon Process Controls Ltd.
  • Page 13: Setting Mode

    Long pressing of the [ENT] key can accelerates displacement. (When the bottom Icons is green. [ENT] key is displacement direction, press [ /TREND] key to switch the direction of displacement) 24-0523 © Icon Process Controls Ltd.
  • Page 14: Function Code

    Function codes indicate the type of operation performed by the server. CRC domain is the result of the “ redundancy check” calculation, which is executed according to the information content. 24-0523 © Icon Process Controls Ltd.
  • Page 15 The entire message frame must be sent in a continuous character stream. When the pause time interval between two characters exceeds 1.5 characters, the information frame is considered incomplete and the receiver does not receive the information frame. 24-0523 © Icon Process Controls Ltd.
  • Page 16 Request: Function Code 1 byte 0x03 Start Address 2 byte 0x0000..0xfffff Read Register Number 2 byte 1...125 Fig.8 : Read and hold register request frame 24-0523 © Icon Process Controls Ltd.
  • Page 17 Start Address 2 byte 0x0000..0xfffff Number of input registers 2 byte 0x0001..0x0078 Number of bytes 1 byte Register Values N x 2 bytes Value Fig.11 : Write Multiple Register Request Frames *N = Register Number 24-0523 © Icon Process Controls Ltd.
  • Page 18 Number of bytes 0x00 Register Value (High byte) 0x0A Register Value (Low byte) 0x01 Register Value (High byte) 0x02 Register Value (Low byte) Figure 13 : Examples of writing multiple register request and response frames 24-0523 © Icon Process Controls Ltd.
  • Page 19 1. If the compiler used by the user has a library function that implements this function, the library function can be called directly, for example, using C language, then you can directly call the C library function memcpy to obtain an integer representation of the floating-point storage format in memory. 24-0523 © Icon Process Controls Ltd.
  • Page 20 S; long int E,M; float D; realbyte0 = byte3; realbyte1 = byte2; realbyte2 = byte1; realbyte3 = byte0; 24-0523 © Icon Process Controls Ltd.
  • Page 21 [00 00 4120]= 10.0; // Main Measured Value [00 00 42 C8] = 100.0; / / Temperature and Voltage Value [00 00 43 48] = 200.0; / / Main measured voltage value [81 E8] represents CRC16 check code; 24-0523 © Icon Process Controls Ltd.
  • Page 22: Maintenance

    When cleaning the plastic shell of the instrument, please use a soft cloth and a soft cleaner to clean the shell. ■ Check whether the wiring on the terminal of the instrument is firm. Pay attention to disconnect the AC or DC power before removing the wiring cover. 24-0523 © Icon Process Controls Ltd.
  • Page 23: Warranty, Returns And Limitations

    Icon Process Controls Ltd for a period of one year from the date of sale of such products. Icon Process Controls Ltd obligation under this warranty is solely...