SystemAir Fantech HERO Series Installation, Operation And Maintenance Manual
SystemAir Fantech HERO Series Installation, Operation And Maintenance Manual

SystemAir Fantech HERO Series Installation, Operation And Maintenance Manual

Heat/energy recovery ventilator (hrv/erv)
Hide thumbs Also See for Fantech HERO Series:

Advertisement

Quick Links

Manuel d'installation, de fonctionnement et de maintenance
HERO SERIES • SÉRIE HERO
Heat/Energy Recovery Ventilator (HRV/ERV)
Ventilateur récupérateur de chaleur/énergie (VRC/VRE)
PARTS IN THE BOX
Heat/Energy Recovery Ventilator, 1 pc
Hanging Bracket, 1 pc
Hanging Chain, 1 pc
Drain Hose Kit, 1 pc
Quick Start Guide, 1 pc
PIÈCES DANS LA BOÎTE
Ventilateur récupérateur de chaleur/énergie, 1 pc
Support muraux, 1 pc
Kit de suspension, 1 pc
Tuyau d'évacuation, 1 pc
Guide de Démarrage Rapide, 1 pc
Your ventilation system should be installed in conformance with the appropriate provincial requirements or, in the absence of
such requirements, with the current edition of the National Building Code, and / or ASHRAE's "Good Engineering Practices".
Votre système de ventilation doit être installé conformément aux exigences de la province où vous habitez ou, à défaut de
telles exigences, conformément à l'édition actuelle du Code national du bâtiment du Canada ou aux « méthodes d'ingénierie
appropriées » de l'ASHRAE.
United States
10048 Industrial Blvd., Lenexa, KS, 66215
Tel.: 800.747.1762 • Fax: 800.487.9915
Canada
50 Kanalflakt Way, Bouctouche, NB, E4S 3M5
Tel.: 800.565.3548 • Fax: 877.747.8116
Fantech reserves the right to modify, at any time and without notice, any or all of its products' features, designs,
components and specifications to maintain their technological leadership position.
Please visit our website www.fantech.net for more detailed technical information.
Fantech se réserve le droit de modifier partiellement ou entièrement, en tout moment et sans préavis, les
caractéristiques, la conception, les composants et les spécifications de ses produits, afin de conserver sa
position de leader de technologie.
S'il vous plaît visitez notre site siteweb www.fantech.net pour des informations techiques plus détaillées.
Installation, Operation, and Maintenance Manual
REGISTER THIS PRODUCT TO
BE REMINDED OF SUGGESTED
PRODUCT CARE SCHEDULE
ENREGISTREZ CE PRODUIT POUR
ÊTRE RAPPELÉ DU PROGRAMME
D'ENTRETIEN SUGGÉRÉ
registration.fantech.app
Literature Item #: 428486
Rev Date: 2025-06-09
Numéro d'article de la littérature : 428486
Date de révision : 2025-06-09

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Fantech HERO Series and is the answer not in the manual?

Questions and answers

Summary of Contents for SystemAir Fantech HERO Series

  • Page 1 Literature Item #: 428486 Installation, Operation, and Maintenance Manual Rev Date: 2025-06-09 Numéro d'article de la littérature : 428486 Date de révision : 2025-06-09 Manuel d’installation, de fonctionnement et de maintenance HERO SERIES • SÉRIE HERO Heat/Energy Recovery Ventilator (HRV/ERV) Ventilateur récupérateur de chaleur/énergie (VRC/VRE) PARTS IN THE BOX Heat/Energy Recovery Ventilator, 1 pc...
  • Page 2 Note Warning/ Information Technical Practical tip Important information note This product earned the ENERGY STAR® by meeting strict energy efficiency guidelines set by Natural Resources Canada and the US EPA. This product meets ENERGY STAR requirements only when used in Canada. To ensure quiet operation of the ENERGY STAR certified H/ERV, each product model must be installed using sound attenuation techniques appropriate for the installation.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS INSTALLATION TYPES ............... . . 4 HRV/ERV ducting for fully Dedicated System .
  • Page 4: Installation Types

    INSTALLATION TYPES Example only – duct configuration may differ depending on the model. HRV/ERV DUCTING FOR FULLY DEDICATED SYSTEM Stale air is drawn from areas requiring local exhaust (bathroom, kitchen, laundry room). Fresh air is distributed to habitable rooms (bedrooms, living room) The HRV/ERV's airflow must be balanced after installation using the procedure found in the Make sure the HRV/ section “AIRFLOW BALANCING”.
  • Page 5: Hrv/Erv Ducting To Forced Air System For Partially Dedicated System

    INSTALLATION TYPES Example only – duct configuration may differ depending on the model. HRV/ERV DUCTING TO FORCED AIR SYSTEM FOR PARTIALLY DEDICATED SYSTEM Forced air system blower must operate when ventilation from HRV/ERV is required. The system should be set to run continuously or interlocked with HRV/ERV.
  • Page 6: Hrv/Erv Ducting To Forced Air System For Simplified Installation

    INSTALLATION TYPES Example only – duct configuration may differ depending on the model. HRV/ERV DUCTING TO FORCED AIR SYSTEM FOR SIMPLIFIED INSTALLATION Forced air system blower must operate when ventilation from HRV/ERV is required. The system should be set to run continuously or interlocked with HRV/ERV.
  • Page 7: Installing The Outdoor Vents

    INSTALLING THE OUTDOOR VENTS RECOMMENDED INSTALLATION Intake • Should be located upstream of prevailing winds from exhaust • At a minimum distance to 900 mm (3') away from dryer vents and furnace exhaust (900 mm) (900 mm) (medium or high efficiency furnaces), 36"...
  • Page 8: Duct Installation

    DUCT INSTALLATION CONNECTING THE DUCTS TO THE HRV/ERV EXHAUST TO FRESH OUTDOOR STALE AIR FRESH AIR OUTDOOR HOOD AIR INTAKE • Ducts should be kept short and have as FROM HOME TO HOME few bends or elbows as possible. • 45º elbows are preferable to 90º. •...
  • Page 9: Installing The Drain

    INSTALLING THE DRAIN FOR HRVs FOR ERVs Install the drain hose making a "P" trap, secure Push the drain cap into the drain hole. the condensate line drain to HRV by sliding into connection. Fill the condensate line with water. MOUNTING OPTIONS WALL MOUNTING BRACKET INSTALLATION MOUNTING KIT INCLUDES:...
  • Page 10: Chain Mount Installation

    MOUNTING OPTIONS CHAIN MOUNT INSTALLATION INSTALLATION CHAIN MOUNTING KIT INCLUDES: DO NOT Connecting appliances to the HRV/ERV is not recommended. These include: • Clothes dryer • Range top • Stovetop fan • Central vacuum system • Bathroom exhaust fans unless they are specifically designed for this purpose •...
  • Page 11: Wall Controls

    WALL CONTROLS * Please see instruction manuals for individual controls for proper wiring and set up of control systems. Ensure that unit is not plugged when connecting the control. The wiring connectors can be removed for easier connection. CENTRAL CONTROLS These cannot be used with another central control (+ →...
  • Page 12 WALL CONTROLS (CONT'D) AUXILIARY CONTROL – These controls can be paired with central controls or combined together. (+ → + ; - → -) *Maintain polarity between the control and the product RTS SERIES FEATURES CONNECTS TO RTS W • Wireless timer •...
  • Page 13: Balancing

    BALANCING Balancing must be completed using the Fantech ECO-Touch ® Programmable Touch Screen Wall Control Supply manometer High High ENTERING BALANCING MODE Exhaust In the options menu during manometer the initial 5 second countdown sequence, long press on "ECO" area for 5 seconds to enter basic balancing mode.
  • Page 14 WIRING DIAGRAM - HERO 100E, 120H, 150H, 200H...
  • Page 15 WIRING DIAGRAM - HERO 150H-EC, 250H-EC (CONT'D)
  • Page 16: Wiring Diagram

    WIRING DIAGRAM (CONT'D) WIRING DIAGRAM TO Standard Accessory Control Contact Standard Furnace Interlock Wiring FORCED AIR SYSTEM THERMOSTAT TERMINALS FOUR WIRE TWO WIRE heating only FOR A FURNACE CONNECTION TO A COOLING SYSTEM: On some newer furnaces and older FURNACE/HEATING thermostats, energizing the R and 24-VOLT G terminal at the furnace has the...
  • Page 17: Control Hierarchy / Operations

    CONTROL HIERARCHY / OPERATIONS Terminal Block Label Description Remote off function (dry contact) – When S+ and S- terminals are shorted together, the ventilation product will be forced into standby mode until the dry contact is opened. Digital communication lines for four-wire controllers. ↓...
  • Page 18: Troubleshooting

    TROUBLESHOOTING Problem Causes Solutions Air is too dry Dehumidistat control is set too low Increase the desired level of humidity. Change ventilation mode from continuous mode to standby. HRV/ERV out of balance Have contractor balance HRV/ERV airflows Air is too humid Dehumidistat control is set too high Reduce the desired level of humidity.
  • Page 19: Filter Location

    FILTER LOCATION Optional Filters: • MERV8/ • MERV13* *HERO 150H, 150H-EC, 200H, & 250H-EC only Electrostatic Filters HRV/ERV MAINTENANCE CHART Maintenance Required Recommended Frequency Date Maintenance Performed Check and Clean Every 3 months or if dirty Electrostatic Filters Check and replace Every 3 months or if dirty MERV8 / MERV13 Filter Check Heat Recovery Core...
  • Page 20 NOTE...
  • Page 21 Numéro d'article de la littérature : 428486 Date de révision : 2025-06-09 Manuel d’installation, de fonctionnement et de maintenance SÉRIE HERO Ventilateur récupérateur de chaleur/énergie (VRC/VRE) PIÈCES DANS LA BOÎTE Ventilateur récupérateur de chaleur/énergie, 1 pc Support muraux, 1 pc Kit de suspension, 1 pc Tuyau d’évacuation, 1 pc Guide de Démarrage Rapide, 1 pc...
  • Page 22 Remarque Avertissement/ Information Information Conseil pratique Remarque technique importante Ce produit a obtenu la certification ENERGY STAR® en respectant les directives strictes d'efficacité énergétique établies par Ressources naturelles Canada et l'EPA des États- Unis. Ce produit répond aux exigences ENERGY STAR uniquement lorsqu'il est utilisé au Canada. Pour assurer un fonctionnement silencieux du VRC/E certifié...
  • Page 23 TABLE DES MATIÈRES TYPES D’INSTALLATION ............... 24 Conduits de VRC/VRE pour un système entièrement spécialisé...
  • Page 24: Types D'installation

    TYPES D’INSTALLATION Exemple seulement : la configuration des conduits peut différer selon le modèle. CONDUITS DE VRC/VRE POUR UN SYSTÈME ENTIÈREMENT SPÉCIALISÉ L’air vicié est aspiré à partir des endroits clés de la maison (salle de bains, cuisine, buanderie). L’air frais est distribué parmi les pièces habitables (chambres à coucher, salon). Le débit d'air du VRC/VRE doit être confirmé...
  • Page 25: Conduits De Vrc/Vre/Système À Air Pulsé Synchronisé Pour Système Partiellement Spécialisé

    TYPES D’INSTALLATION Exemple seulement : la configuration des conduits peut différer selon le modèle. CONDUITS DE VRC/VRE/SYSTÈME À AIR PULSÉ SYNCHRONISÉ POUR SYSTÈME PARTIELLEMENT SPÉCIALISÉ Le ventilateur du système à air pulsé doit fonctionner lorsque la ventilation par VRC/VRE est requise. Le système doit être configuré pour fonctionner en continu ou être en synchronisation avec le VRE/VRE.
  • Page 26: Vrc/Vre/Système À Air Pulsé Synchronisé Pour Une Système Simplifiée

    TYPES D’INSTALLATION Exemple seulement : la configuration des conduits peut différer selon le modèle. VRC/VRE/SYSTÈME À AIR PULSÉ SYNCHRONISÉ POUR UNE SYSTÈME SIMPLIFIÉE Le ventilateur du système à air pulsé doit fonctionner lorsque la ventilation par VRC/VRE est requise. Le système doit être configuré pour fonctionner en continu ou être en synchronisation avec le VRE/VRE.
  • Page 27: Installation Des Évents Extérieurs

    INSTALLATION DES ÉVENTS EXTÉRIEURS INSTALLATION RECOMMANDÉE Admission • Doivent être situés en amont des vents dominants de l’échappement. • Doit être située à une distance minimum de 900 mm (3 pi) de la hotte d’évacuation, des 900 mm 900 mm évents de la sécheuse et de l’évacuation de la (3 pi) min.
  • Page 28: Installation Des Conduits

    INSTALLATION DES CONDUITS RELIER LES CONDUITS AU VRC/VRE ÉVACUATION VERS ADMISSION D’AIR AIR VICIÉ AIR FRAIS L'EXTÉRIEUR FRAIS EXTÉRIEUR • Les conduits doivent être courts et DE LA MAISON VERS LA MAISON présenter le moins de plis ou coudes possibles. •...
  • Page 29: Installation Du Tuyau D'évacuation

    INSTALLATION DU TUYAU D’ÉVACUATION POUR VRCs POUR VREs Installez le tuyau d’évacuation en formant un piège en « P », puis Insérez le bouchon d’évacuation dans le trou fixez le tuyau d’évacuation du condensat au VRC en le glissant d’évacuation. dans le raccord. Remplissez le tuyau de condensat d’eau. OPTIONS DE FIXATION MURAL D'INSTALLATION UTILISEZ LES INSTRUCTIONS...
  • Page 30: Installation À L'aide De Chaînes

    OPTIONS DE FIXATION INSTALLATION À L’AIDE DE CHAÎNES LE KIT DE MONTAGE DE LA CHAÎNE D'INSTALLATION COMPREND: À NE PAS FAIRE Il n’est pas recommandé de relier des appareils au VRC/VRE, dont les : • Sécheuses • Cuisinières • Hottes de cuisinière •...
  • Page 31: Commandes Murales

    COMMANDES MURALES * Veuillez consulter les manuels d’instructions des dispositifs de commande individuels pour connaître la bonne configuration de câblage et l’installation adéquate des systèmes de commande. Assurez-vous que l’appareil n’est pas branché lorsque vous reliez la commande. Les raccords de câblage peuvent être retirés pour faciliter le branchement. COMMANDES CENTRALES Ceux-ci ne peuvent pas être utilisés avec une autre commande centrale (+ →...
  • Page 32 COMMANDES MURALES (CONT'D) COMMANDE AUXILIAIRE – Ces commandes peuvent être associées à des commandes centrales ou combinées ensemble. (+ → + ; - → -) *Conserver la polarité entre la commande et le produit SÉRIE RTS CARACTÉRISTIQUES CONNEXIONS RTS-W • Minuterie sans fil •...
  • Page 33: Équilibrage

    ÉQUILIBRAGE L’équilibrage doit être réalisé à l’aide de la commande murale à écran tactile programmable Fantech ECO-Touch MD . Manomètre d’alimentation Élevé Élevé ACCÉDER AU MODE D’ÉQUILIBRAGE Faible Faible Manomètre Dans le menu d’options, lors de la d’évacuation séquence de décompte initiale de 5 secondes, appuyez sur la zone « ECO »...
  • Page 34: Schéma Électroniques - Hero 120H, 150H, 200H

    SCHÉMA ÉLECTRONIQUES - HERO 100E, 120H, 150H, 200H...
  • Page 35 SCHÉMA ÉLECTRONIQUES - HERO 150H-EC, 250H-EC (SUITE)
  • Page 36 SCHÉMA ÉLECTRONIQUES (SUITE) CONNEXION ÉLECTRIQUE Bornes pour Accessoire de Contrôle Standard Fil de verrouillage de chaudière alternatif À UN SYSTÈME À AIR BORNES DE PULSÉ THERMOSTAT QUATRE FILS DEUX FILS chauffage DISPOSITIF DE VERROUILLAGE seulement DANS LE CAS D'UNE FOURNAISE RACCORDÉE À UN SYSTÈME DE REFROIDISSEMENT BORNIER 24V...
  • Page 37: Hiérarchie / Opérations De Contrôle

    HIÉRARCHIE / OPÉRATIONS DE CONTRÔLE Étiquette de bornier Description Fonction d'arrêt à distance (contact sec) – lorsque les bornes S+ et S- sont court-circuitées, le produit de venti- lation est forcé en mode veille jusqu'à ce que le contact sec soit ouvert. Lignes de communication numériques pour contrôleurs à...
  • Page 38: Dépannage

    DÉPANNAGE Problème Causes Solutions L’air est trop sec. Le réglage du déshumidistat est trop faible. Augmentez le taux d’humidité souhaité. Changez le mode de ventilation de continu à en attente. Le VRC/VRE est déséquilibré. Demandez à un entrepreneur d’équilibrer les débits d’air du VRC/VRE. L’air est trop humide.
  • Page 39: Emplacement Du Filtre

    EMPLACEMENT DU FILTRE Filtres optionnels: - MERV8 - MERV13* * HERO 150H, 150H-EC, 200H, et 250H-EC seulement. Filtres électrostatiques TABLEAU D’ENTRETIEN DU VRC/VRE Entretien requis Fréquence recommandée Date du service d’entretien Vérifier et nettoyer les filtres Tous les 3 mois ou en cas de saleté électrostatiques Nettoyer et remplacer le filtre Tous les 3 mois ou en cas de saleté...
  • Page 40: Warranty

    Fantech reserves the right to make technical changes. Fantech se réserve le droit d’apporter des modifications For updated documentation please refer to www.fantech.net techniques. Pour de la documentation à jour, veuillez consulter le site www.fantech.net. Fantech MD WARRANTY (GARANTIE) Make a scan of the QR code above to access Scannez le code QR ci-dessus pour accéder à...

Table of Contents