Installation Instructions for the Kanda

General instructions
Preparation
Installation
Repairs
Technical details Kanda
General instructions
The Kanda is tested in accordance with international
EN13229 standardization. This hearth can be connected
to a chimney to which several stoves are connected. The
duct for the chimney has a diameter of 200 mm. The
connection to the convection system has a diameter of
150 mm.
The heating device must be placed by an acknowledged
installer and according to the installation instructions
given below. The national and local rules and regulations
for placing and using wood-burning stoves are equally
applicable. WANDERS does not give any guarantee
if the Kanda is connected or installed incompletely or
incorrectly.
It is not allowed to place the stove in:
• Arcades and corridors accessible to the public.
• Stairwells, except in buildings with no more than 2
dwellings.
• Spaces where highly flammable or explosive materials
are used.
Roof slope x larger than 23°
23
23
24
27
28
• Spaces where an exhaust system is used or where a
mechanical exhaust system is placed, except when
the air supply is taken directly from outside to assure
a hazardless combustion.
Preparation
The chimney flue
Before placing the stove you must observe the following
points:
• If the stove is connected to an existing chimney, you
must first have the chimney professionally cleaned
and checked by a qualified chimney sweep company.
Any cut-off valves or stop valves must be removed.
• The flue tube of the stove must be connected with the
chimney without diversions.
• The underpressure in the chimney must be at least 12
Pa or 0.12 mbar.
• The chimney flue must always end up in outlet area 1
(see the drawing and the table below)
Roof slope x smaller than 23°
23