3. Grounded, cord-connected machines intended for
use on a supply circuit having a nominal rating
between 150 - 250 volts, inclusive:
If the machine is intended for use on a circuit that has an
outlet that looks like the one illustrated in Fig. C, the
machine will have a grounding plug that looks like the
plug illustrated in Fig. C. Make sure the machine is
connected to an outlet having the same configuration as
the plug. No adapter is available or should be used with
this machine. If the machine must be re-connected for
use on a different type of electric circuit, the re-
connection should be made by qualified service
personnel; and after re-connection, the machine should
comply with all local codes and ordinances.

EXTENSION CORDS

Use proper extension cords. Make sure your extension cord is in good condition and is a 3-wire
extension cord which has a 3-prong grounding type plug and matching receptacle which will accept the machine's
plug. When using an extension cord, be sure to use one heavy enough to carry the current of the machine. An
undersized cord will cause a drop in line voltage, resulting in loss of power and overheating. Fig. D-1 or D-2, shows
the correct gauge to use depending on the cord length. If in doubt, use the next heavier gauge. The smaller the gauge
number, the heavier the cord.
MINIMUM GAUGE EXTENSION CORD
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES
Ampere
Total Length
Rating
Volts
of Cord in Feet
0-6
120
up to 25
0-6
120
25-50
0-6
120
50-100
0-6
120
100-150
6-10
120
up to 25
6-10
120
25-50
6-10
120
50-100
6-10
120
100-150
10-12
120
up to 25
10-12
120
25-50
10-12
120
50-100
10-12
120
100-150
12-16
120
up to 25
12-16
120
25-50
12-16
120
GREATER THAN 50 FEET NOT RECOMMENDED
Fig. D-1
Gauge of
Ampere
Extension Cord
Rating
18 AWG
0-6
16 AWG
0-6
16 AWG
0-6
14 AWG
0-6
18 AWG
6-10
16 AWG
6-10
14 AWG
6-10
12 AWG
6-10
16 AWG
10-12
16 AWG
10-12
14 AWG
10-12
12 AWG
10-12
14 AWG
12-16
12 AWG
12-16
12-16
7
GROUNDED OUTLET BOX
CURRENT
CARRYING
PRONGS
GROUNDING BLADE
IS LONGEST OF THE 3 BLADES
Fig. C
MINIMUM GAUGE EXTENSION CORD
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES
Total Length
Volts
of Cord in Feet
240
up to 50
240
50-100
240
100-200
240
200-300
240
up to 50
240
50-100
240
100-200
240
200-300
240
up to 50
240
50-100
240
100-200
240
200-300
240
up to 50
240
50-100
240
GREATER THAN 100 FEET NOT RECOMMENDED
Fig. D-2
Gauge of
Extension Cord
18 AWG
16 AWG
16 AWG
14 AWG
18 AWG
16 AWG
14 AWG
12 AWG
16 AWG
16 AWG
14 AWG
12 AWG
14 AWG
12 AWG

Hide quick links: