Advertisement

GIOTTO BT A ULTRA 36
INSTALLATION AND USER'S MANUAL
ELECTROMECHANICAL CONTROL DEVICE FOR VEHICULAR
INSTRUCCIONES DE USO Y DE INSTALACION
BARRIERS
AUTOMATISMOS ELECTROMECANICOS PARA BARRÉRAS
VEHICULAR
Caution! Read "Warnings" inside carefully!
¡Atención¡ Leer atentamente las "Advertencias" en el interior!
www.BFTGateOpeners.com | (800) 878-7829 | Sales@BFTGateOpeners.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GIOTTO ULTRA 36 XL and is the answer not in the manual?

Questions and answers

Summary of Contents for BFT GIOTTO ULTRA 36 XL

  • Page 1 GIOTTO BT A ULTRA 36 INSTALLATION AND USER’S MANUAL ELECTROMECHANICAL CONTROL DEVICE FOR VEHICULAR INSTRUCCIONES DE USO Y DE INSTALACION BARRIERS AUTOMATISMOS ELECTROMECANICOS PARA BARRÉRAS VEHICULAR Caution! Read “Warnings” inside carefully! ¡Atención¡ Leer atentamente las “Advertencias” en el interior! www.BFTGateOpeners.com | (800) 878-7829 | Sales@BFTGateOpeners.com...
  • Page 2 - Entradas separadas para los dispositivos de seguridad - Entradas de mando configurables - Receptor radio incorporado rolling-code con clonación de transmisores. La tarjeta cuenta con tablero de bornes desmontable para facilitar aún más su mantenimiento o sustitución. GIOTTO BT A ULTRA 36...
  • Page 3 Attenzione! Leggere attentamente le “Avvertenze” all’interno! Caution! Read “Warnings” inside carefully! Attention! Veuillez lire attentivement les Avertissements qui se trouvent à l’intérieur! Achtung! Bitte lesen Sie aufmerksam die „Hinweise“ im Inneren! ¡Atención¡ Let op! Lees de “Waarschuwingen” aan de binnenkant zorgvuldig! EQUIPMENT- HERRAMIENTAS Ø10 Wall Pared GIOTTO BT A ULTRA 36 -...
  • Page 4: Cable Arrangement

    CABLE ARRANGEMENT PREPARACIÓN DE LOS CABLES LH barrier RH barrier barrera izquierda barrera derecha 5x18AWG Not supplied No asignadas en el equipamiento base DIMENSIONS - DIMENSIONES " " " 11/16 GIOTTO BT A ULTRA 36...
  • Page 5: Installation

    INSTALACIÓN With foundation plate embedded in ground Con placa de cimentación empotrada en el suelo 13/16" With anchor bolts - Con tirantes D1+R1 13/16" 10,5 " Not supplied, No asignadas en el equipamiento base GIOTTO BT A ULTRA 36 -...
  • Page 6 TRANSFORMING FROM LH BARRIER TO RH - TRANSFORMACIÓN DE BARRERA IZQUIERDA A DERECHA LH barrier RH barrier barrera izquierda barrera derecha BOOM ASSEMBLY: refer to the OMEGA ES/PS manual ESMONTAJE DE LA BARRA: véase el manual OMEGA ES/PS GIOTTO BT A ULTRA 36...
  • Page 7 45° OK - 45 ° - 45 ° 0 ° BOOM LENGTH (FEET) / LONGITUD DEL BRAZO (PIES) GIOTTO BT A ULTRA 36 GIOTTO BT A ULTRA 36 XL " 9' 10 " 11' 5 " 13' 1 " 16' 4 "...
  • Page 8: Control Unit Connections

    CONTROL UNIT CONNECTIONS - CONEXIÓN A LA CENTRAL DE CONTROL GIOTTO BT A ULTRA 36...
  • Page 9 AUX 3 = 14 AUX 0 = 14 26 27 Connection To Car-park Management System, Conexion Al Sistema De Gestion De Aparcamientos AUX 3 = 12 AUX 3 = 12 26 27 26 27 GIOTTO BT A ULTRA 36 -...
  • Page 10 10 11 20 2126 27 41 42 43 50 51 52 60 61 6 OPEN 10 11 20 2126 27 41 42 43 50 51 52 60 61 62 70 71 72 73 74 75 OPEN STOP CLOSE CLOSE STOP GIOTTO BT A ULTRA 36...
  • Page 11 O 01 Scroll up Scroll down Conÿrm/Switch on display Exit Menù GIOTTO BT A ULTRA 36...
  • Page 12 : funcionamiento semi-aut, en ediÿcios : funcionamiento con hombre presente RADIO anad start suelte O 01 tecla deseada LEYENDA Desplazar hacia arriba fine Desplazar hacia abajo Conÿrmación/ Encendido pantalla Retorno al menú principal GIOTTO BT A ULTRA 36 -...
  • Page 13 P1 + sp. d ecel - esp. d ecel. - PRG ok [55] erlangsamungstrecke dist. d ecel - esp. d ecel default P1 + accel. - acceler - PRG ok accel - beschleunigung default fine-end-fin GIOTTO BT A ULTRA 36 -...
  • Page 14 SAFE 2 = 7 (˜ 6) SAFE 2 SLAVE = SAFE 2 MASTER TO CONNECT SEVERAL PHOTOCELLS, REFER TO FIG. P - PARA LA CONEXIÓN DE VARIAS FOTOCÉLULAS CONSULTAR LA FIG. P <3s 8888 rst8 STOP 8888 GIOTTO BT A ULTRA 36...
  • Page 15 SAFETY EDGE SAFETY EDGE SAFETY EDGE 8,2Kohm 5% 8,2Kohm 5% Maximum number of tested devices: 6 (but no more than 4 per type), Número máximo dispositivos comprobados: 6 (pero no más de 4 por tipo), GIOTTO BT A ULTRA 36 -...
  • Page 16 Check if the SAFE inputs are correctly set; during the Error in setting the SAFE inputs operation of opposed barriers, SAFE2 must be set up ERf3 as safety edge. Fig. L * X = 0,1,…,9,A,B,C,D,E,F 0--- 10-- 150- 1520 password GIOTTO BT A ULTRA 36 -...
  • Page 17 Refer to the “Command input configuration” table. Configurable command input 2 (N.O.) - Default CLOSE. IC 2 START E / START I / OPEN / CLOSE / TIMER / OPEN Refer to the “Command input configuration” table. GIOTTO BT A ULTRA 36...
  • Page 18 SAFE logic= 8 - Input configured as Bar 8k2 (fig.N, ref.5). Input for resistive edge 8K2. The command reverses movement for 2 sec. * (If “D” type devices are installed (as defined by EN12453), connect in unverified mode, foresee mandatory maintenance at least every six months. GIOTTO BT A ULTRA 36 -...
  • Page 19 Force exerted by the barrier while closing. WARNING: It affects impact force directly: make sure that Leaf force during closing CLS. F ORCE current safety requirements are met with the set value (*). Install anti-crush safety devices where necessary (**). GIOTTO BT A ULTRA 36...
  • Page 20 Input configured as Phot cl test (tested photocell active during closing only). Configuration of safety input SAFE 2. SAFE 2 Input configured as Bar, safety edge. Input configured as Bar, tested safety edge. Input configured as Bar 8k2. GIOTTO BT A ULTRA 36 -...
  • Page 21 MASTER opposite leaves in local network: the control unit is the master in an opposite leaves network with no smart module (fig.L) Identifies board address from 0 to 119 in a local BFT net wor k connec tion. [ ___ ]...
  • Page 22 ON = Enables remote programming of cards via a previously memorized W LINK transmitter. It remains enabled for 3 minutes from the time the W LINK transmitter is last pressed. OFF= W LINK programming disabled. GIOTTO BT A ULTRA 36 -...
  • Page 23 Error en la configuración de las entradas SAFE ERf3 trapuestas SAFE2 debe configurarse como borde de seguridad. Fig. L * X = 0,1,…,9,A,B,C,D,E,F 0--- 10-- 150- 1520 password GIOTTO BT A ULTRA 36...
  • Page 24 Salida de alimentación para dispositivos de seguridad verificados (transmisor de células fotoeléctricas y transmisor VSAFE 24V-2~/+24V de borde sensible). Salida activa solo durante el ciclo de maniobra. La alimentación del dispositivo verificado se toma de los bornes 50-52. GIOTTO BT A ULTRA 36 -...
  • Page 25 El mando invierte el movimiento durante 2 seg. (*) Si se instalan dispositivos de tipo “D” (tal como los define la EN12453), conectados en modo no comprobado, establecer un mantenimiento obligatorio con frecuencia al menos semestral. GIOTTO BT A ULTRA 36...
  • Page 26 ATENCIÓN: Influye directamente en la fuerza de impacto: comprobar que con el FUERZA AP valor configurado se respeten las normas de seguridad vigentes (*). Si fuera necesario instalar dispositivos de seguridad antiaplastamiento (**) . GIOTTO BT A ULTRA 36 -...
  • Page 27 El impulso de las entradas configuradas como Start E, Start I no tiene efecto durante el cierre. de cierre Inversión Funcionamiento estándar (barrera izquierda). dirección de INV. D IRECC. A P. Se invierte el sentido de apertura respecto al funcionamiento estándar (barrera derecha). apertura GIOTTO BT A ULTRA 36...
  • Page 28 MASTER hojas contrapuestas en red local: la tarjeta es el master en una red de hojas contrapuestas sin BFT.) módulo inteligente. (fig.L) Identifica la dirección de 0 a119 de la tarjeta en una conexión de red BFT local. [ ___ ] Dirección INDIRIZZO (véase apartado MÓDULOS OPCIONALES U-LINK)
  • Page 29 ON = Habilita la programación a distancia de las entradas mediante un transmisor W LINK anteriormente memorizado. Esta habilitación permanece activa 3 minutos desde la última pulsación del radiomando W LINK. OFF= Programación W LINK deshabilitada. GIOTTO BT A ULTRA 36...
  • Page 30 USER’S MANUAL: MANUAL OPERATION MAMANUAL DE USO: ACCIONAMIENTO MANUAL GIOTTO BT A ULTRA 36...
  • Page 31 ACCESSORIES - ACCESORIOS 5/8" RH barrier barrera derecha Ø5 " Not supplied, No asignadas en el equipamiento base VEHICLE LOOP DETECTOR DETECTOR DE VEHÍCULOS DE LAZO INDUCTIVO COMPACTA A20-180 PHOTOCELL FOTOCÉLULA Not supplied, No asignadas en el equipamiento base, www.BFTGateOpeners.com | (800) 878-7829 | Sales@BFTGateOpeners.com...

Table of Contents