IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES
IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM
THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN
ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE
WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN
FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE
FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM. WE SUGGEST THAT THE BOTTLE FILLING STATION
AND WATER COOLER BE PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER (GFCI).
INSTALLER
EZWSR / LZWSR Bottle Fillers are among the easiest to install on the market today.
To insure you install these models easily and correctly, PLEASE READ THESE
SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK
YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND
OTHER APPLICABLE CODES. After installation, leave these instructions with the
Cooler for future reference.
EZWSR*1D, *2D
LZWSR*1D, *2D
R
-F
®
ETRO
R
-F
®
ETRO
THIS IS AN INDOOR APPLICATION ONLY.
ALL SERVICE TO BE PERFORMED BY AN
SAFETY GLASSES
GLOVES
3/4" WRENCH OR CRESCENT
WRENCH
5/16" NUT DRIVER
UTILITY KNIFE
TAPE MEASURE
PENCIL
CENTER PUNCH
1/2" SOCKET & RATCHET WRENCH
5/32" ALLEN WRENCH
7/64" ALLEN WRENCH
Page 1
WWW.RESTROOMDIRECT.COM
INSTALLATION & USE MANUAL
B
F
IT
OTTLE
ILLING
B
F
IT
OTTLE
ILLING
IMPORTANT
AUTHORIZED SERVICE PERSON.
TOOLS REQUIRED
BUT NOT PROVIDED:
704 • 937• 2673
129 Oakpark Dr., Unit A, Mooresville, NC 28115
U
NIT
U
NIT
1000004729 (Rev. A - 09/18)

Advertisement

loading
Need help?

Need help?

Do you have a question about the ezH2O EZWSR 2D Series and is the answer not in the manual?

Questions and answers

Summarization of Contents

Installer Information
Important Installation Notes
Grounding considerations and GFCI protection for electrical equipment.
Water Cooler Preparation and System Setup
Water Cooler Preparation Steps
Steps for removing panels and disconnecting water lines from the cooler.
Filter Installation and Pressurization
Installing the filter and pressurizing the water system for operation.
Bi-Level Model Modifications
Specific plumbing modifications for bi-level cooler configurations.
Installation Diagrams and Schematics
Rough-In Dimension Diagrams
Diagrams showing standard and alternate rough-in dimensions for models.
Plumbing Diagram Configurations
Visual representations of plumbing setups for different unit types.
Bottle Filler Assembly and Preparation
Basin Assembly and Preparation
Steps for removing, preparing, and reassembling the basin assembly.
Quick Connect Fittings Operation
Explanation of how to attach and release tubes using quick connect fittings.
Wiring Diagrams
Bottle Filler 115V Wiring
Wiring diagram for the 115V bottle filler unit.
Bi-Level Unit Wiring
Wiring diagrams for non-refrigerated and refrigerated sides of bi-level units.
Bottle Filler Installation Process
Mounting and Connecting the Bottle Filler
Instructions for mounting the unit, connecting lines, wires, and power.
Filter Installation and Final Checks
Installing the filter cartridge and performing final checks and startup procedures.
Wiring Modification for Bi-Level Units
Counter Advancement Issue Resolution
Procedure to modify wiring for bi-level units with advancing bottle filler counters.
Control Board Programming
Software Verification and Access
Verify software version and access the programming menu.
System Configuration Settings
Configure filter monitor, unit type, filter capacity, and bottle count.
Alternate Filter Mounting Location
Drilling and Mounting Instructions
Steps for drilling holes and mounting the filter assembly in an alternate location.
Parts List
Filter Parts
List of filter assembly components and part numbers.
Replacement Part Kits
List of available replacement part kits and their descriptions.