Edwards APG-MP-NW16 ST/ST Instructions Manual

Edwards APG-MP-NW16 ST/ST Instructions Manual

Active pirani gauge
Table of Contents

Advertisement

Instruction Manual | Betriebsanleitung | Mode d'emploi
Description
Beschreibung
Description
APG-M-NW16 AL
APG-M-NW25 ST/ST
APG-L-NW16 AL
APG-L-NW25 ST/ST
APG-M-NW16 ST/ST
APG-M-15OD ST/ST
APG-L-NW16 ST/ST
APG-L-15OD ST/ST
APG-MP-NW25 ST/ST
APG-MP-NW16 ST/ST
APG-MP-150D ST/ST
Original Instructions
Issue L / Ausgabe L / Edition L
Active Pirani Gauge
Aktiv-Pirani-Messröhren
Jauge active Pirani
Bestellnummer
Numéro de Référence
D021-71-885
Item Number
D021-71-000
D021-72-000
D021-73-000
D021-74-000
D021-75-000
D021-76-000
D021-77-000
D021-78-000
D021-82-000
D021-85-000
D021-86-000

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the APG-MP-NW16 ST/ST and is the answer not in the manual?

Questions and answers

Summarization of Contents

Introduction
Scope and definitions
Defines the manual's scope and terminology for the Active Pirani Gauge.
Description
Provides a detailed overview of the Active Pirani Gauge (APG).
Gas dependency
Explains how gas type affects pressure readings and output signals.
Technical data
Mechanical data
Details physical specifications like dimensions, mass, and enclosure ratings.
Performance, operating and storage conditions
Outlines operational limits, environmental conditions, and altitude restrictions.
Electrical data
Covers power supply, voltage, ripple, resistance, and connector specifications.
Materials exposed to vacuum
Lists materials used in vacuum contact for different APG models.
Installation
Unpack and inspect
Instructions for unpacking and checking the APG for damage.
Fit the APG to the vacuum system
Guidance on mounting the APG securely within the vacuum system.
Electrical connection
Procedures for connecting the APG's electrical components.
Operation
Pressure measurement
How to accurately measure pressure using the APG.
Set-point adjustment
Steps to adjust the APG's set-point pressure.
Maintenance
Atmosphere and vacuum adjustment
Procedure for calibrating APG for ambient and vacuum pressure.
Clean the Filter
Instructions on how to safely clean the APG filter.
Fault finding
Guidance on troubleshooting common APG issues and signals.
Storage and disposal
Storage
Recommendations for storing the APG safely.
Disposal
Guidelines for safe and environmentally compliant disposal.
Spares and accessories
Introduction
Information on obtaining spare parts and accessories.
Spares
Details on available spare parts, like filter replacement kits.
Accessories
Lists suitable cables and surge suppressors for the APG.

Table of Contents