Table C-2. Configuration Manager Messages - Dell Precision 400 User Manual

Midsize systems
Hide thumbs Also See for Precision 400:
Table of Contents

Advertisement

Message
ERROR: Could not read
NVS, Error= Internal
Error Code .
ERROR: Failed NVS
write. Error= Internal
Error Code .
ERROR: Failed to acti-
vate device, CSN= Card
Select Number .
NOTE: For the full name of an abbreviation or acronym used in this table, see the Glossary.
Table C-2. Configuration Manager Messages (continued)
Probable Cause
An attempt to read the
NVRAM failed.
An attempt to write to
NVRAM failed.
A Plug and Play expansion
card could not be activated.
Corrective Action
See the chapter titled "Getting Help" in your
Diagnostics and Troubleshooting Guide for
instructions.
Run the Dell Diagnostics to verify the integrity of
your system NVRAM. See the chapter titled
"Running the Dell Diagnostics" in your Diagnos-
tics and Troubleshooting Guide for instructions.
If you are unable to determine the cause of the
error, see the chapter titled "Getting Help" in your
Diagnostics and Troubleshooting Guide for instruc-
tions.
Use the following procedure:
1.
Exit the ICU and turn off your system.
2.
Remove the Plug and Play expansion card
that could not be activated.
Follow steps 2 through 6 of "Removing an
Expansion Card" in Chapter 8, and then
return to this procedure.
3.
Reinstall the Plug and Play expansion
card.
Follow steps 5 through 9 of "Installing an
Expansion Card" in Chapter 8, and then
return to this procedure.
If you still receive the error message, contact the
manufacturer of the Plug and Play expansion card
for assistance.
ISA Configuration Utility Messages
C-7

Advertisement

Table of Contents
loading