Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Daikin Manuals
Air Compressor
RKXYQ-T
Installation and operation manual
Daikin RKXYQ-T Installation And Operation Manual
Compressor unit for indoor installation
Hide thumbs
1
2
3
4
5
Table Of Contents
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
page
of
48
Go
/
48
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Table of Contents
To Access the Field Setting Components
Field Setting Components
To Access Mode 1 or 2
To Use Mode 1 (and Default Situation)
To Use Mode 2
Mode 1 (and Default Situation): Monitoring Settings
Mode 2: Field Settings
To Connect the PC Configurator to the Compressor Unit
Commissioning
Precautions When Commissioning
Checklist before Commissioning
Checklist During Commissioning
About the Test Run
To Perform a Test Run (7-Leds Display)
To Perform a Test Run (7-Segment Display)
Correcting after Abnormal Completion of the Test Run
Hand-Over to the User
Troubleshooting
Solving Problems Based on Error Codes
Error Codes: Overview
Technical Data
Piping Diagram: Compressor Unit and Heat Exchanger Unit
Wiring Diagram: Compressor Unit
Disposal
Advertisement
Quick Links
Download this manual
Installation and operation manual
VRV IV compressor unit for indoor installation
Installation and operation manual
RKXYQ5T8Y1B
English
VRV IV compressor unit for indoor installation
RKXYQ8T7Y1B
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the RKXYQ-T and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for Daikin RKXYQ-T
Air Compressor Daikin VRV IV RKXYQ5T8Y1B Series Installation And Operation Manual
Compressor unit for indoor installation (48 pages)
Air Compressor Daikin VRV IV i Series Installation And Operation Manual
Compressor unit for indoor installation (48 pages)
Air Compressor Daikin VRV IV RKXYQ8T7Y1B Installation And Operation Manual
Compressor unit for indoor installation (44 pages)
Air Compressor Daikin RKXYQ5T7Y1B Installation And Operation Manual
Vrv iv compressor unit for indoor installation (32 pages)
Air Compressor Daikin ZH(C)3LSF Service Manual
Semi-hermetic single screw compressor version 3 (51 pages)
Air Compressor Daikin Clima-Flex CLIC Series Installation, Operation And Maintenance Manual
Air-cooled scroll compressor chiller water generator unit, refrigerant hfc-410a or 454b 50/60 hz (118 pages)
Air Compressor Daikin DWSC079 Installation, Operation And Maintenance Manual
Single/dual compressor centrifugal chillers (67 pages)
Air Compressor Daikin Climaa-Flex DWP Series Installation, Operation And Maintenance Manual
Direct expansion unit with scroll compressor (52 pages)
Air Compressor Daikin DWSC 050 Installation, Operation And Maintenance Manual
(62 pages)
Air Compressor Daikin Clima-Flex CLIWP Series Control Manual
Direct expansion unit with scroll compressor (36 pages)
Summarization of Contents
1 About the documentation
1.1 About this document
Details the purpose and scope of this manual, including target audience and documentation set.
3 User safety instructions
3.1 General
General safety advice for users regarding appliance operation, care, and potential hazards.
3.2 Instructions for safe operation
Specific instructions to ensure safe operation, covering electrical hazards, hot parts, and ventilation.
4 About the system
4.1 System layout
Diagram illustrating the system layout, including units, piping, and connections.
6 Operation
6.1 Operation Range and Modes
Covers operating temperature/humidity limits and different modes like cooling, heating, and automatic.
6.2 System Operation Procedures
Guides on operating the system with and without changeover switches, including specific unit operations.
6.3 Special Programs and Settings
Details the dry program, air flow adjustment, and master user interface setup for system control.
7 Maintenance and service
7.1 About the refrigerant
Provides information on refrigerant type, safety, and environmental regulations related to its use.
7.2 Service and Warranty Information
Covers warranty details and recommended maintenance procedures for unit longevity and performance.
8 Troubleshooting
8.1 Error codes: Overview
Explains how to interpret error codes displayed on the indoor unit interface and the steps to take.
8.2 Symptoms that are NOT system malfunctions
Details common operational behaviors that are not actual malfunctions, such as normal noises or display indications.
11 About the box
11.1 Compressor Unit Procedures
Guides on removing accessories, transportation stays, and EPS from the compressor unit.
12 About the units and options
12.1 Compressor and Heat Exchanger Unit Details
Details the specifications and intended use of compressor and heat exchanger units.
12.2 System Layout
Illustrates the system layout, showing connections between indoor, outdoor, and heat exchanger units.
12.3.1 Options for Compressor and Heat Exchanger Units
Lists available options for controlling cooling/heating from a central location, like the cool/heat selector.
13 Unit installation
13.1 Preparing the installation site
Specifies service space requirements and installation environment considerations for the compressor unit.
13.2 Opening the unit
Provides instructions on how to safely open the compressor unit for access.
13.3 Mounting the compressor unit
Offers guidelines for securely mounting the compressor unit, considering vibration and structural integrity.
14 Piping installation
14.1 Refrigerant Piping Preparation
Covers requirements, material, sizing, branch kits, and length/height specifications for refrigerant piping.
14.2 Connecting Refrigerant Piping
Guides on using stop valves, service ports, removing pinched pipes, and connecting piping to the compressor.
14.3 Checking and Insulating Refrigerant Piping
Covers leak testing, vacuum drying, and insulation procedures for ensuring piping integrity.
14.4 Refrigerant Charging Procedures
Covers precautions, calculation of refrigerant amount, charging process, and error codes.
15 Electrical installation
15.1 About electrical compliance
Details electrical compliance requirements, focusing on harmonic currents for the RKXYQ8 model.
15.2 Safety device requirements
Specifies requirements for safety devices, such as residual current operated circuit breakers.
15.3 Field wiring: Overview
Provides an overview of field wiring, including power supply and communication wiring between units.
15.4 To connect the electrical wiring on the compressor unit
Step-by-step instructions for connecting electrical wiring to the compressor unit, referencing wiring diagrams.
15.5 To check the insulation resistance of the compressor
Guides on measuring the insulation resistance of the compressor using a mega-tester.
16 Configuration
16.1 Making field settings
Introduces field setting components like push buttons, displays, and DIP switches for system configuration.
16.1.4 To access mode 1 or 2
Explains how to navigate between default, mode 1, and mode 2 settings for configuration and monitoring.
16.1.6 To use mode 2
Provides instructions for making field settings to configure the system using mode 2.
16.1.8 Mode 2: Field settings
Details specific field settings available in mode 2 for cooling/heating comfort, fan speed, and low noise operation.
17 Commissioning
17.1 Precautions when commissioning
Highlights critical precautions to take before and during test operations to ensure safety and proper system checks.
17.2 Checklist before commissioning
Provides a checklist of items to verify after installation and before powering up the unit for commissioning.
17.3 Test Run Procedures
Details the test run process, including pre-run checks, execution for different models, and handling abnormal completions.
19 Troubleshooting
19.1 Solving problems based on error codes
Explains how to interpret error codes displayed on the indoor unit interface and the steps to take.
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the RKXYQ-T and is the answer not in the manual?
Questions and answers