evertz 7708LRA Manual

evertz 7708LRA Manual

L-band fiber receiver
Table of Contents

Advertisement

Quick Links

1.
OVERVIEW ....................................................................................................................................... 1
2.
INSTALLATION ................................................................................................................................. 2
2.1. 7708LRA/7708LR-H CONNECTIONS ...................................................................................... 3
2.2. CARE AND HANDLING OF OPTICAL FIBER .......................................................................... 3
2.2.1. Handling and Connecting Fibers .................................................................................... 3
3.
7708LRA/7708LR-H SPECIFICATIONS ............................................................................................ 4
3.1. RF OUTPUT .............................................................................................................................. 4
3.2. OPTICAL INPUT ....................................................................................................................... 4
3.3. ELECTRICAL ............................................................................................................................ 4
3.4. PHYSICAL ................................................................................................................................ 4
4.
STATUS INDICATORS AND DISPLAYS ........................................................................................... 5
4.1. 7708LRA/7708LR-H STATUS INDICATORS ............................................................................ 5
5.
JUMPER POSITIONS ....................................................................................................................... 6
5.1. 7708LRA/7708LR-H JUMPERS ............................................................................................... 6
BY THE GLOBAL FRAME STATUS ......................................................................................... 6
5.3. CONFIGURING THE MODULE FOR FIRMWARE UPGRADES ............................................... 7
5.4. FACTORY AND BDM JUMPERS ............................................................................................. 7
6.
DOT-MATRIX DISPLAY .................................................................................................................... 8
6.1. 7708LRA/7708LR-H CONTROLLED PARAMETERS ............................................................. 10
6.1.1. Adjusting the Optical Power Alarm Thresholds ............................................................ 10
6.1.3. Selecting the Output Gain Mode .................................................................................. 11
6.1.4. Adjusting the RF Output Gain ...................................................................................... 12
6.1.5. Adjusting the AGC Target Level .................................................................................. 12
6.1.6. Enabling/Disabling Squelch Mode ............................................................................... 12
6.1.7. Setting the Card Edge Display Orientation................................................................... 13
6.1.8. Resetting Factory Defaults .......................................................................................... 13
7708LRA and 7708LR-H L-Band Fiber Receiver

TABLE OF CONTENTS

Revision 1.1
7700 MultiFrame Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 7708LRA and is the answer not in the manual?

Questions and answers

Summarization of Contents

INSTALLATION
7708LRA/7708LR-H CONNECTIONS
Connects fiber optic cable to transmitter and provides dual electrical outputs.
CARE AND HANDLING OF OPTICAL FIBER
Precautions for preventing fiber damage and ensuring proper connection.
7708LRA/7708LR-H SPECIFICATIONS
RF OUTPUT
Specifies frequency, connector, impedance, return loss, and output levels.
OPTICAL INPUT
Details number of inputs, connector type, wavelength, and sensitivity.
ELECTRICAL
Lists voltage, power consumption, and EMI/RFI compliance.
STATUS INDICATORS AND DISPLAYS
7708LRA/7708LR-H STATUS INDICATORS
Explains the nine LED indicators for module and signal status.
JUMPER POSITIONS
7708LRA/7708LR-H JUMPERS
Identifies jumper locations for various functions on the card edge.
CONFIGURING THE MODULE FOR FIRMWARE UPGRADES
Details the procedure for updating module firmware using the UPGRADE jumper.
FACTORY AND BDM JUMPERS
Advises that FACTORY and BDM jumpers should not be installed.
DOT-MATRIX DISPLAY
7708LRA/7708LR-H CONTROLLED PARAMETERS
Describes how to adjust parameters via the card edge display menu.
Adjusting the Optical Power Alarm Thresholds
How to set high/low input optical power alarm points.
TRANSMITTER CONTROLLABLE PARAMETERS
How to monitor and adjust transmitter parameters via SmartMON.
7708LRA/7708LR-H MONITORED CONDITIONS AND PARAMETERS
How to view monitored receiver parameters via the STAT menu.
TRANSMITTER MONITORED PARAMETERS
How to view monitored transmitter parameters via SmartMON.
VISTALINK REMOTE MONITORING/CONTROL - 7703 VERSIONS
WHAT IS VISTALINK®?
Overview of Evertz's remote monitoring and configuration platform.
7708LRA/7708LR-H VistaLINK® Monitored Parameters
Lists parameters that can be monitored via VistaLINK.
7708LRA/7708LR-H VistaLINK® Controlled Parameters
Lists parameters that can be controlled via VistaLINK.
7708LRA/7708LR-H VistaLINK® Traps
Lists trap events for VistaLINK monitoring.

Table of Contents