Keypad Installation
To install a double-gang keypad, you will need a
UL/CSA approved plastic 32ci double-gang
electrical box.
Note the minimal clearance around the box for
the bezel. This is larger than a typical light
switch cover, so additional space may be
required.
For best viewing and usage, the UNO-TS2
should be mounted at thermostat height, or
about 59" from the floor.
Route CAT-5 wire to the junction box from the con-
troller.
Use the supplied 110 punchdown tool to con-
nect each wire to its corresponding color
labeled on the punchdown terminal.
Mount the keypad in the electrical box and
attach the cover plate. Repeat the steps until all
keypads are installed.
32ci plastic junction box
Touchscreen Bezel Removal
To remove the bezel from the front of an
installed touchscreen, you will need a flat screw-
driver. Place the screwdriver blade in the slot
between the bezel and the molding, located
below the "R" on the bottom edge of the bezel.
Twist the blade until a loud click is heard; this
UNO-TS2 Touchscreen Installation
Width
difference
0.72"
UNO-TS2 bezel size vs. standard wallplate
UNO-TS2 touchscreen
sound is the bezel locking tabs releasing from
the frame catch. The bezel can now be lifted
from the touchscreen
To replace the bezel, center it over the front of
the touchscreen and press firmly until the bezel
clicks into place.
INSTALLER GUIDE
Size of UNO-TS2 bezel
6.0" W x 4.875" H
Size of standard 2-gang box
4.0" W x 3.81" H
Size of standard 2-gang wallplate
4.56" W x 4.5" H
UNO-TS2 Bezel
Width
difference
0.72"